IEC contactor, TeSys Deca, nonreversing, 40A, 30HP at 480VAC, 3 phase, 3 pole, 3 NO, 230VAC 50/60Hz coil, open style

0 Reviews
$348.75 $150.00
200 in stock

Unconditional Satisfaction Guarantee
No Shipping Fees Above 30
2 Months to Decide. Returns Simplified.

Specifications

  • [Uc] Control Circuit Voltage: 230 V AC 50/60 Hz
  • [Ue] Rated Operational Voltage: power circuit <= 690 V AC 25…400 Hz || power circuit <= 300 V DC
  • Range Of Product: TeSys Deca
  • Contactor Application: resistive load || motor control
  • Product Or Component Type: contactor
  • Range: TeSys || TeSys Deca
  • Utilisation Category: AC-4 || AC-1 || AC-3 || AC-3e
  • [Ie] Rated Operational Current: 60 A 60 C) <= 440 V AC AC-1 power circuit || 40 A 60 C) <= 440 V AC AC-3 power circuit || 40 A 60 C) <= 440 V AC AC-3e power circuit
  • Poles Description: 3P
  • Device Short Name: LC1D

Contractual warranty

  • Warranty: 18 months

Complementary

  • Non-Overlap Time: 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
  • Minimum Switching Current: 5 mA signalling circuit
  • Power Dissipation Per Pole: 2.4 W AC-3 || 5.4 W AC-1 || 2.4 W AC-3e
  • Average Impedance: 1.5 mOhm – Ith 60 A 50 Hz power circuit
  • Auxiliary Contact Composition: 1 NO + 1 NC
  • [Ith] Conventional Free Air Thermal Current: 10 A 60 C signalling circuit || 60 A 60 C power circuit
  • Control Circuit Voltage Limits: 0.3…0.6 Uc -40-70 C drop-out AC 50/60 Hz || 0.8…1.1 Uc -40-60 C operational AC 50 Hz || 0.85…1.1 Uc -40-60 C operational AC 60 Hz || 1…1.1 Uc 60-70 C operational AC 50/60 Hz
  • Mounting Support: rail || plate
  • Contact Compatibility: M2
  • Control Circuit Type: AC 50/60 Hz
  • Safety Reliability Level: B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
  • Pollution Degree: 3
  • Insulation Resistance: > 10 MOhm signalling circuit
  • Rated Breaking Capacity: 800 A 440 V power circuit IEC 60947
  • Irms Rated Making Capacity: 140 A AC signalling circuit IEC 60947-5-1 || 250 A DC signalling circuit IEC 60947-5-1 || 800 A 440 V power circuit IEC 60947
  • Associated Fuse Rating: 10 A gG signalling circuit IEC 60947-5-1 || 80 A gG <= 690 V type 1 power circuit || 80 A gG <= 690 V type 2 power circuit
  • [Uimp] Rated Impulse Withstand Voltage: 6 kV IEC 60947
  • Inrush Power In Va: 140-140 VA 60 Hz 0.75 20 C) || 160-160 VA 50 Hz 0.75 20 C)
  • Pole Contact Composition: 3 NO
  • Connections – Terminals: control circuit lugs-ring terminals 8 mm || power circuit lugs-ring terminals 16.5 mm
  • Coil Technology: without built-in suppressor module
  • Operating Time: 4…19 ms opening || 12…26 ms closing
  • Minimum Switching Voltage: 17 V signalling circuit
  • Maximum Operating Rate: 3600 cyc/h 60 C
  • Signalling Circuit Frequency: 25…400 Hz
  • Tightening Torque: control circuit 1.7 N.m lugs-ring terminals flat 6 mm M3.5 || control circuit 1.7 N.m lugs-ring terminals Philips No 2 M3.5 || power circuit 6 N.m lugs-ring terminals hexagonal 10 mm M6 || control circuit 1.7 N.m screw clamp terminals pozidriv No 2 || power circuit 2.5 N.m screw clamp terminals pozidriv No 2
  • Electrical Durability: 1.4 Mcycles 60 A AC-1 <= 440 V || 1.5 Mcycles 40 A AC-3 <= 440 V || 1.5 Mcycles 40 A AC-3e <= 440 V
  • Mechanical Durability: 6 Mcycles
  • Auxiliary Contacts Type: mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
  • Compatibility Code: LC1D
  • Hold-In Power Consumption In Va: 13-13 VA 60 Hz 0.3 20 C) || 15-15 VA 50 Hz 0.3 20 C)
  • Overvoltage Category: III
  • Maximum Horse Power Rating: 5 hp 230/240 V at AC 50/60 Hz for 1 phase || 10 hp 230/240 V at AC 50/60 Hz for 3 phase || 30 hp 575/600 V at AC 50/60 Hz for 3 phase || 10 hp 200/208 V at AC 50/60 Hz for 3 phase || 3 hp 115 V at AC 50/60 Hz for 1 phase || 30 hp 460/480 V at AC 50/60 Hz for 3 phase
  • Motor Power Kw: 18.5 kW 380…400 V AC 50/60 Hz AC-3) || 11 kW 220…230 V AC 50/60 Hz AC-3) || 22 kW 415…440 V AC 50/60 Hz AC-3) || 22 kW 500 V AC 50/60 Hz AC-3) || 30 kW 660…690 V AC 50/60 Hz AC-3) || 9 kW 400 V AC 50/60 Hz AC-4) || 18.5 kW 380…400 V AC 50/60 Hz AC-3e) || 11 kW 220…230 V AC 50/60 Hz AC-3e) || 22 kW 415…440 V AC 50/60 Hz AC-3e) || 22 kW 500 V AC 50/60 Hz AC-3e) || 30 kW 660…690 V AC 50/60 Hz AC-3e)
  • [Ui] Rated Insulation Voltage: power circuit 600 V CSA || power circuit 600 V UL || signalling circuit 690 V IEC 60947-1 || signalling circuit 600 V CSA || signalling circuit 600 V UL || power circuit 690 V IEC 60947-4-1
  • [Icw] Rated Short-Time Withstand Current: 320 A 40 C – 10 s power circuit || 720 A 40 C – 1 s power circuit || 72 A 40 C – 10 min power circuit || 165 A 40 C – 1 min power circuit || 100 A – 1 s signalling circuit || 120 A – 500 ms signalling circuit || 140 A – 100 ms signalling circuit
  • Heat Dissipation: 4-5 W 50/60 Hz
  • Protective Cover: with

Offer Sustainability

  • Rohs Exemption Information: Yes
  • Mercury Free: Yes
  • Environmental Disclosure: ENVPEP1503009EN
  • Sustainable Offer Status: Green Premium product
  • Pvc Free: Yes
  • Toxic Heavy Metal Free: Yes
  • Reach Regulation: Free of Substances of Very High Concern above the threshold
  • California Proposition 65: WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Reach Free Of Svhc: Yes
  • Weee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
  • China Rohs Regulation: Pro-active China RoHS declaration (out of China RoHS legal scope)
  • Circularity Profile: ENVEOLI1503009EN
  • Eu Rohs Directive: Compliant

Environment

  • Product Certifications: UL || CSA || GOST || CCC
  • Height: 122 mm
  • Standards: CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
  • Climatic Withstand: IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
  • Net Weight: 0.85 kg
  • Flame Retardance: V1 conforming to UL 94
  • Protective Treatment: THIEC 60068-2-30
  • Ip Degree Of Protection: IP20 front face IEC 60529
  • Mechanical Robustness: vibrations contactor open 2 Gn, 5…300 Hz) || vibrations contactor closed 4 Gn, 5…300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 10 Gn for 11 ms)
  • Operating Altitude: 0…9842.52 ft (0…3000 m)
  • Fire Resistance: 850 C IEC 60695-2-1
  • Width: 55 mm
  • Depth: 120 mm
  • Permissible Ambient Air Temperature Around The Device: -40-60 C || 60-70 C with derating

Downloads

Spec Sheet

CAD

Tesys – 3D-CAD – LC1D40A6B7 (pdf)
3P EVLK CONT 40A 18,5KW – 3D CAD – MCADPP0003731_2D-back (dxf)
Tesys – 3D-CAD – LC1D40A6B7_2D-front (dxf)
3P EVLK CONT 40A 18,5KW – 3D CAD – MCADPP0003731_2D-bottom (dwg)
Tesys – 3D-CAD – LC1D40A6B7_2D-top (dxf)
3P EVLK CONT 40A 18,5KW – 3D CAD – MCADPP0003731_2D-front (dxf)
Tesys – 3D-CAD – LC1D40A6B7_2D-isometric (dxf)
Tesys – 3D-CAD – LC1D40A6B7_2D-right (dwg)
3P EVLK CONT 40A 18,5KW – 3D CAD – MCADPP0003731_2D-right (dwg)
3P EVLK CONT 40A 18,5KW – 3D CAD – MCADPP0003731_2D-isometric (dwg)
Tesys – 3D-CAD – LC1D40A6B7_2D-back (dwg)
Tesys – 3D-CAD – LC1D40A6B7_2D-bottom (dxf)
Tesys – 3D-CAD – LC1D40A6B7_2D-left (dwg)
3P EVLK CONT 40A 18,5KW – 3D CAD – MCADPP0003731_2D-top (dxf)
Tesys – 3D-CAD – LC1D40A6B7_2D-top (dwg)
3P EVLK CONT 40A 18,5KW – 3D CAD – MCADPP0003731_2D-back (dwg)
3P EVLK CONT 40A 18,5KW – 3D CAD – MCADPP0003731_2D-right (dxf)
3P EVLK CONT 40A 18,5KW – 3D CAD – MCADPP0003731_3D-simplified (stp)
3P EVLK CONT 40A 18,5KW – 3D CAD – MCADPP0003731_2D-isometric (dxf)
3P EVLK CONT 40A 18,5KW – 3D CAD – MCADPP0003731_2D-left (dwg)
Tesys – 3D-CAD – LC1D40A6B7_2D-left (dxf)
Tesys – 3D-CAD – LC1D40A6B7_Pdf3d (pdf)
3P EVLK CONT 40A 18,5KW – 3D CAD – MCADPP0003731_2D-left (dxf)
3P EVLK CONT 40A 18,5KW – 3D CAD – MCADPP0003731_2D-front (dwg)
Tesys – 3D-CAD – LC1D40A6B7_2D-right (dxf)
3P EVLK CONT 40A 18,5KW – 3D CAD – MCADPP0003731_2D-bottom (dxf)
Tesys – 3D-CAD – LC1D40A6B7_2D-bottom (dwg)
Tesys – 3D-CAD – LC1D40A6B7_2D-front (dwg)
Tesys – 3D-CAD – LC1D40A6B7_2D-isometric (dwg)
Tesys – 3D-CAD – LC1D40A6B7_3D-simplified (stp)
Tesys – 3D-CAD – LC1D40A6B7_2D-back (dxf)
3P EVLK CONT 40A 18,5KW – 3D CAD – MCADPP0003731_2D-top (dwg)

Brochure

TeSys Refresh Informational Guide – Brochure – 998-20803955_GMA-US (pdf)
Industrial Automation and Control Product Lines Brochure – 998-20256927_2019_Line_Card_GM (pdf)
Square D Model 6 Intelligent Motor Control Centers Brochure – 8998BR0001 (pdf)

Circularity Profile

Eoli_Contactors, TeSys D, 40, 50, 65A – EoLI_ENVEOLI1503009 (pdf)

Certificate

CSA Certificate_ TeSys D_LC1D40A-80A&LC2D40A-80A&LC1DT60A-80A&LC2DT60A-80A – CoFC_80091429_EN (pdf)
CB Certificate TeSys D – LC1D40A-80A&LC2D40A-80A&LC1DT60A-80A&LC2DT60A-80A_Le Vaudreuil – LC.D40A-80A_DT60-80_HU-003711-M1 (pdf)
Certificate_TeSys D_ LC1D40A-80A&LC2D40A-80A&LC1DT60A-80A&LC2DT60A-80A&DPE40-65 – E48539-20080202-CertificateofCompliance (pdf)
EU RO MR Type Approval Certificate_TeSys D_LC1D40A-80A&LC2D40A-80A&LC1DT60A-80A&LC2DT60A-80A – LC.D40A-80A_LC.DT60A-80A_MRE000000G-rev1 (pdf)
DNV Type Approval Certificate_TeSys D_LC1D40A-80A&LC2D40A-80A&LC1DT60A-80A&LC2DT60A-80A – LC.D40A-80A_LC.DT60A-80A_TAE000033T-revision1 (pdf)
CB Certificate TeSys D – LC1D40A-80A&LC2D40A-80A&LC1DT60A-80A&LC2DT60A-80A_Batam – LC.D40A-80A_DT60A-80A_Batam_HU_003718_M1 (pdf)

Data Bulletin

Motor Control Solutions for the North American Market Data Bulletin – 8536DB0901+R04_23 (pdf)

Instruction sheet

LC1D..A6 3-pole contactor with ring-type connection 40 to 80 A AC-3 – Instruction sheet – 1727249_01A55-11 (pdf)

Environmental Disclosure

PEP_Contactors, TeSys D, 3P(3 NO) – AC-3 – <= 440 V 50 A – 230 V AC 50/60 Hz coil – PEP+ecopassport+SCHN-2015-030-EN (pdf)

Declaration of conformity

EU Declaration TeSys D_LC1D40A-80A&LC2D40A-80A&LC1DT60A-80A&LC2DT60A-80A – PP_EU_Doc_LC.D40A-80A_SC16040411F.docx (pdf)
UKCA Declaration TeSysD_LC1D40A-80A&LC2D40A-80A&LC1DT60A-80A&LC2DT60A-80A – UK_Doc_LC.D40A-80A_SC16040411B-UK.docx (pdf)

Videos

Locating the TeSys D Line IEC Contactor Model Number | Schneider Electric Support Mounting & Unmounting TeSys D Contactors to DIN Rails | Schneider Electric Support Mounting Auxiliary Contact Block to TeSys D Series Contactor | Schneider Electric Support Installing & Removing Mechanical and Electrical Interlock on TeSys D | Schneider Electric Support Removing Auxiliary Contact Block from TeSys D Series Contactor | Schneider Electric Support

Shipping Info Standard Shipping
Free Shipping We offer free shipping on orders over $30. Please check the free - shipping eligibility at checkout.
Delivery Time: It usually takes 3-5 business days for standard shipping. Please note that this is an estimated time frame and may be affected by local holidays, and unforeseen circumstances.