product-details

Control relay, TeSys K, 2 NO + 2 NC, lt or eq to 690V, 220VDC standard coil

0 Reviews
$53.54 $26.77
200 in stock

Unconditional Satisfaction Guarantee
No Shipping Fees Above 30
2 Months to Decide. Returns Simplified.

Specifications

  • [Ue] Rated Operational Voltage: <= 690 V <= 400 Hz
  • Control Circuit Type: DC standard
  • [Uc] Control Circuit Voltage: 220 V DC
  • Contactor Application: control circuit
  • Product Or Component Type: control relay
  • Product Name: TeSys CAK
  • Range: TeSys
  • Pole Contact Composition: 2 NO + 2 NC
  • Utilisation Category: DC-13 || AC-15
  • Device Short Name: CA3K

Contractual warranty

  • Warranty: 18 months

Complementary

  • Minimum Switching Current: 5 mA
  • Height: 58 mm
  • Control Circuit Voltage Limits: operational 0.8…1.15 Uc 50 C) || drop-out 0.1…0.75 Uc 50 C)
  • Non Overlap Distance: 0.5 mm
  • [Ith] Conventional Free Air Thermal Current: 10 A 50 C
  • Mounting Support: plate || rail
  • Immunity To Microbreaks: 2 ms
  • Hold-In Power Consumption In W: 3-3 W 20 C
  • Insulation Resistance: > 10 MOhm
  • Irms Rated Making Capacity: 110 A IEC 60947
  • Associated Fuse Rating: 10 A gG IEC 60947 || 10 A gG VDE 0660
  • Net Weight: 0.225 kg
  • Connections – Terminals: screw clamp terminals 1 1.5-4 mmsolid || screw clamp terminals 2 1.5-4 mmsolid || screw clamp terminals 1 0.75-4 mmflexible with cable end || screw clamp terminals 2 0.75-4 mmflexible without cable end || screw clamp terminals 1 0.34-1.5 mmflexible with cable end || screw clamp terminals 2 0.34-1.5 mmflexible without cable end
  • Minimum Switching Voltage: 17 V
  • Maximum Operating Rate: 10000 cyc/h
  • Tightening Torque: 1.3 N.m screw clamp terminals flat 6 mm || 1.3 N.m screw clamp terminals Philips No 2 6 mm || 1.3 N.m screw clamp terminals pozidriv No 2
  • Mechanical Durability: 20 Mcycles
  • Inrush Power In W: 3-3 W 20 C)
  • Operating Time: 10 ms coil de-energisation and NO opening || 30…40 ms coil energisation and NO closing || 15 ms coil de-energisation and NC closing || 25…35 ms coil energisation and NC opening
  • Width: 45 mm
  • Depth: 57 mm
  • [Ui] Rated Insulation Voltage: 690 V IEC 60947 || 750 V VDE 0110 group C || 690 V BS 5424 || 600 V CSA C22.2 No 14
  • Heat Dissipation: 3-3 W

Offer Sustainability

  • Rohs Exemption Information: Yes
  • Mercury Free: Yes
  • Environmental Disclosure: ENVPEP1503003EN
  • Sustainable Offer Status: Green Premium product
  • Toxic Heavy Metal Free: Yes
  • Reach Regulation: Free of Substances of Very High Concern above the threshold
  • California Proposition 65: WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Reach Free Of Svhc: Yes
  • Weee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
  • China Rohs Regulation: Pro-active China RoHS declaration (out of China RoHS legal scope)
  • Circularity Profile: ENVEOLI1503003EN
  • Eu Rohs Directive: Compliant

Environment

  • Product Certifications: CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
  • Mechanical Robustness: vibrations contactor open2 Gn, 5…300 Hz IEC 60068-2-6 || vibrations contactor closed4 Gn, 5…300 Hz IEC 60068-2-6 || shocks contactor open10 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed15 Gn for 11 ms IEC 60068-2-27
  • Ambient Air Temperature For Operation: -25-50 C
  • Standards: EN/IEC 60947-4-1 || GB/T 14048.4 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1
  • Flame Retardance: V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102
  • Ambient Air Temperature For Storage: -50-80 C
  • Protective Treatment: TC IEC 60068
  • Ip Degree Of Protection: IP2X
  • Operating Altitude: 6561.68 ft (2000 m) without derating

Downloads

Spec Sheet

CAD

3 or 4 pole contactor TeSys LP1K, 6A to 20A, with screw clamp terminals – 3D CAD – MCADPP0003359 (pdf)
3 or 4 pole contactor TeSys LP1K, 6A to 20A, with screw clamp terminals – 3D CAD – MCADPP0003359_3D-simplified (stp)
CA3KN22MD_CAD_DOC – CA3KN22MD_2D+Front+View (dxf)
3 or 4 pole contactor TeSys LP1K, 6A to 20A, with screw clamp terminals – 3D CAD – MCADPP0003359_2D-bottom (dxf)
3 or 4 pole contactor TeSys LP1K, 6A to 20A, with screw clamp terminals – 3D CAD – MCADPP0003359_2D-top (dwg)
3 or 4 pole contactor TeSys LP1K, 6A to 20A, with screw clamp terminals – 3D CAD – MCADPP0003359_2D-left (dwg)
3 or 4 pole contactor TeSys LP1K, 6A to 20A, with screw clamp terminals – 3D CAD – MCADPP0003359_2D-right (dxf)
CA3KN22MD_CAD_DOC – CA3KN22MD_2D+Front+View (dwg)
3 or 4 pole contactor TeSys LP1K, 6A to 20A, with screw clamp terminals – 3D CAD – MCADPP0003359_2D-left (dxf)
3 or 4 pole contactor TeSys LP1K, 6A to 20A, with screw clamp terminals – 3D CAD – MCADPP0003359_2D-back (dwg)
IEC Industrial Control Relay (K-Line), CA2KN, CA3KN, CA4KN – E0702001-01 (dxf)
3 or 4 pole contactor TeSys LP1K, 6A to 20A, with screw clamp terminals – 3D CAD – MCADPP0003359_2D-top (dxf)
3 or 4 pole contactor TeSys LP1K, 6A to 20A, with screw clamp terminals – 3D CAD – MCADPP0003359_2D-isometric (dwg)
3 or 4 pole contactor TeSys LP1K, 6A to 20A, with screw clamp terminals – 3D CAD – MCADPP0003359_2D-isometric (dxf)
3 or 4 pole contactor TeSys LP1K, 6A to 20A, with screw clamp terminals – 3D CAD – MCADPP0003359_2D-back (dxf)
IEC Industrial Control Relay (K-Line), CA2KN, CA3KN, CA4KN – E0702001-01 (dwg)
CA3KN22MD_CAD_DOC – CA3KN22MD_3D (stp)
CA3KN22MD_CAD_DOC – CA3KN22MD_2D+Right+Side+View (dwg)
3 or 4 pole contactor TeSys LP1K, 6A to 20A, with screw clamp terminals – 3D CAD – MCADPP0003359_2D-bottom (dwg)
3 or 4 pole contactor TeSys LP1K, 6A to 20A, with screw clamp terminals – 3D CAD – MCADPP0003359_2D-right (dwg)
3 or 4 pole contactor TeSys LP1K, 6A to 20A, with screw clamp terminals – 3D CAD – MCADPP0003359_2D-front (dwg)
3 or 4 pole contactor TeSys LP1K, 6A to 20A, with screw clamp terminals – 3D CAD – MCADPP0003359_2D-front (dxf)
CA3KN22MD_CAD_DOC – CA3KN22MD_2D+Right+Side+View (dxf)

Instruction sheet

LC1-K contactor – Instruction Sheet – 1378085_01A55_15 (pdf)

Technical Drawing

Technical drawing for CA3KN22MD_CAD_DOC – CA3KN22MD_2D+Front+View (dwg)
Technical drawing for IEC Industrial Control Relay (K-Line), CA2KN, CA3KN, CA4KN – E0702001-01 (dxf)
Technical drawing for CA3KN22MD_CAD_DOC – CA3KN22MD_2D+Front+View (dxf)
Technical drawing for CA3KN22MD_CAD_DOC – CA3KN22MD_2D+Right+Side+View (dwg)
Technical drawing for IEC Industrial Control Relay (K-Line), CA2KN, CA3KN, CA4KN – E0702001-01 (dwg)
Technical drawing for CA3KN22MD_CAD_DOC – CA3KN22MD_2D+Right+Side+View (dxf)
Technical drawing for IEC Industrial Control Relay (K-Line), CA2KN, CA3KN, CA4KN – E0702001-01 (pdf)
CA3KN22MD_2DSalesDrawing_PDF – CA3KN22MD_2D+Sales+Drawing (pdf)

Certificate

UL_Certificate_TeSys K_CA3KN_CA4KN&CAK…S207&CAK…S335 – E39281-19930527-CertificateofCompliance (pdf)
CB Certificate TeSys K_CA2KN,CA3KN,CA4KN – CB_CA.KN_LV_CN52919-A1 (pdf)
CSA Certificate_ TeSys K_LC.K_LP.K_CA.KN_CAK_LA1KN_LA4K – COFC_80120004_EN (pdf)

Environmental Disclosure

PEP_TeSys LC1K09-K16 – PEP+ecopassport+SCHN-2015-025-EN_1 (pdf)

Technical illustration

Illustration: Dimensions Drawing Industrial Control Relay K-Line – TI_DIM_E0702001-01.svg

Declaration of conformity

EU_Declaration_TeSys K_CA2-KN, CA3-KN, CA4-KN – EU_Doc_CA.KN+SC16041414B (pdf)
UKCA Declaration TeSys K_CA.KN – UK_Doc_CA2KN_CA3KN_CA4KN_SC16041414B-UK.docx (pdf)

Circularity Profile

Eoli_Contactors, TeSys K contactor – 3P – AC-3 <= 440 V 9 A – 1 NO aux. – 220…230 V AC coil – EoLI_ENVEOLI1503003_1 (pdf)

Shipping Info Standard Shipping
Free Shipping We offer free shipping on orders over $30. Please check the free - shipping eligibility at checkout.
Delivery Time: It usually takes 3-5 business days for standard shipping. Please note that this is an estimated time frame and may be affected by local holidays, and unforeseen circumstances.