product-details

Magnetic latching contactor,TeSys F,3P(3NO),AC-3 <=440V 185A,380400V AC coil

0 Reviews
$1,969.83 $149.00
200 in stock

Unconditional Satisfaction Guarantee
No Shipping Fees Above 30
2 Months to Decide. Returns Simplified.

Specifications

  • Product Certifications: CB Scheme || UL || CSA || EAC || CE || UKCA
  • [Ue] Rated Operational Voltage: 1000 V AC 25…200 Hz
  • Power Dissipation Per Pole: 12 W AC-3 || 26 W AC-1
  • Average Impedance: 0.36 mOhm – Ith 275 A 50 Hz
  • Standards: EN/IEC 60947-1 || EN/IEC 60947-4-1 || JIS C8201-4-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1
  • Control Circuit Type: AC 50/60 Hz
  • [Uc] Control Circuit Voltage: 380 V AC 50/60 Hz
  • Contactor Application: motor control || resistive load
  • Rated Breaking Capacity: 1800 A 220…440 V || 1600 A 500 V || 600 A 1000 V || 1200 A 660/690 V
  • Product Or Component Type: magnetic latching contactor
  • Irms Rated Making Capacity: 2100 A
  • Product Name: TeSys F
  • Associated Fuse Rating: 200 A aM <= 440 V || 315 A BS88 <= 440 V || 315 A gG <= 440 V
  • Connections – Terminals: bars 2 25 x 3 mm || lugs-ring terminals 1 150-150 mm || connector 1 150-150 mm || power circuit bolted connection
  • Range: TeSys
  • Pole Contact Composition: 3 NO
  • Utilisation Category: AC-3 || AC-1 || AC-4
  • [Ie] Rated Operational Current: 185 A 40 C) <= 440 V AC AC-3 || 275 A 40 C) <= 440 V AC AC-1 || 170 A 40 C) <= 440 V AC AC-4
  • Maximum Operating Rate: 120 cyc/h 40 C
  • Tightening Torque: 18 N.m
  • Mechanical Durability: 1 Mcycles
  • Poles Description: 3P
  • Operating Time: 35…40 ms latching || 50…100 ms unlatching
  • Motor Power Kw: 90 kW 400 V AC 50/60 Hz AC-4)
  • [Ui] Rated Insulation Voltage: 1000 V IEC 60158-1 || 1000 V IEC 60947-4 || 1000 V BS 775 || 1500 V VDE 0110 group C
  • Device Application: control
  • Device Short Name: CR1F
  • [Icw] Rated Short-Time Withstand Current: 1500 A 40 C – 1 s || 1500 A 40 C – 5 s || 1500 A 40 C – 10 s || 920 A 40 C – 30 s || 740 A 40 C – 1 min || 500 A 40 C – 3 min || 400 A 40 C – 10 min

Contractual warranty

  • Warranty: 18 months

Complementary

  • Control Circuit Voltage Limits: latching 0.85…1.1 Uc || unlatching 0.85…1.1 Uc
  • Average Coil Consumption: 1600 VA AC 50/60 Hz latching || 8 VA AC 50/60 Hz unlatching

Offer Sustainability

  • Rohs Exemption Information: Yes
  • Mercury Free: Yes
  • Environmental Disclosure: ENVPEP080208EN
  • Sustainable Offer Status: Green Premium product
  • Pvc Free: Yes
  • Reach Regulation: Reference contains Substances of Very High Concern above the threshold
  • California Proposition 65: WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Weee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
  • China Rohs Regulation: Product out of China RoHS scope. Substance declaration for your information.
  • Circularity Profile: ENVEOLI100418
  • Eu Rohs Directive: Compliant

Environment

  • Ambient Air Temperature For Operation: -15-70 C
  • Height: 174 mm
  • Net Weight: 4.6 kg
  • Ambient Air Temperature For Storage: -60-80 C
  • Protective Treatment: TC
  • Operating Altitude: 9842.52 ft (3000 m) without derating
  • Width: 168.5 mm
  • Depth: 181 mm

Downloads

Spec Sheet

CAD

TeSys F magnetic latching contactor – 3P (3NO) – 185 A – AC-3 – 3D CAD – MCADPP0003380_2D-isometric (dwg)
TeSys F magnetic latching contactor – 3P (3NO) – 185 A – AC-3 – 3D CAD – MCADPP0003380_3D-simplified (stp)
TeSys F magnetic latching contactor – 3P (3NO) – 185 A – AC-3 – 3D CAD – MCADPP0003380_2D-left (dwg)
TeSys F magnetic latching contactor – 3P (3NO) – 185 A – AC-3 – 3D CAD – MCADPP0003380_2D-front (dwg)
TeSys F magnetic latching contactor – 3P (3NO) – 185 A – AC-3 – 3D CAD – MCADPP0003380_2D-left (dxf)
TeSys F magnetic latching contactor – 3P (3NO) – 185 A – AC-3 – 3D CAD – MCADPP0003380_2D-top (dwg)
TeSys F magnetic latching contactor – 3P (3NO) – 185 A – AC-3 – 3D CAD – MCADPP0003380_2D-back (dwg)
TeSys F magnetic latching contactor – 3P (3NO) – 185 A – AC-3 – 3D CAD – MCADPP0003380_2D-back (dxf)
TeSys F magnetic latching contactor – 3P (3NO) – 185 A – AC-3 – 3D CAD – MCADPP0003380_2D-isometric (dxf)
TeSys F magnetic latching contactor – 3P (3NO) – 185 A – AC-3 – 3D CAD – MCADPP0003380_2D-bottom (dwg)
TeSys F magnetic latching contactor – 3P (3NO) – 185 A – AC-3 – 3D CAD – MCADPP0003380 (pdf)
TeSys F magnetic latching contactor – 3P (3NO) – 185 A – AC-3 – 3D CAD – MCADPP0003380_2D-front (dxf)
TeSys F magnetic latching contactor – 3P (3NO) – 185 A – AC-3 – 3D CAD – MCADPP0003380_2D-right (dwg)
TeSys F magnetic latching contactor – 3P (3NO) – 185 A – AC-3 – 3D CAD – MCADPP0003380_2D-bottom (dxf)
TeSys F magnetic latching contactor – 3P (3NO) – 185 A – AC-3 – 3D CAD – MCADPP0003380_2D-top (dxf)
TeSys F magnetic latching contactor – 3P (3NO) – 185 A – AC-3 – 3D CAD – MCADPP0003380_2D-right (dxf)

Environmental Disclosure

TeSys LC1F185-225 – ENVPEP080208EN (pdf)

Catalog

TeSys catalogue – 2020 – chapter B9 high power contactors TeSys F,V, FG, CR1F – B9+-++High+power+contactors_EN+(web) (pdf)

Circularity Profile

Eoli_Contactors, TeSys F, TeSys LC1F185-225 – ENVEOLI100418EN (pdf)
End-of-Life Instructions TeSys LC1F185 to LC1F225 – ENVEOLI100418EN_LC1F185_20100615 (pdf)

Declaration of conformity

EU Declaration TeSys F LC.F115-800 – M_LC.F115-800_SC16041111G (pdf)
UKCA Declaration TeSys F_LC.F115-800_CR1F150-630 – UK_LC.F115-800_SC16041111A-UK (pdf)

Instruction sheet

CR1F150/F630 Magnetic latching contactors – Instruction Sheet – 146838701A50_08 (pdf)

Videos

Removing and Replacing Coil from TeSys LC1F F Series Contactor | Schneider Electric Support

Shipping Info Standard Shipping
Free Shipping We offer free shipping on orders over $30. Please check the free - shipping eligibility at checkout.
Delivery Time: It usually takes 3-5 business days for standard shipping. Please note that this is an estimated time frame and may be affected by local holidays, and unforeseen circumstances.