Specifications

  • Product Or Component Type: motor circuit breaker
  • Product Name: TeSys GV3 || TeSys Deca
  • Range: TeSys Deca
  • Device Application: motor protection
  • Device Short Name: GV3P
  • Trip Unit Technology: thermal-magnetic

Contractual warranty

  • Warranty: 18 months

Complementary

  • Line Rated Current: 13 A
  • [Ue] Rated Operational Voltage: 690 V AC 50/60 Hz IEC 60947-2
  • Height: 132 mm
  • Phase Failure Sensitivity: yes IEC 60947-4-1
  • Rated Duty: continuous IEC 60947-4-1
  • Network Type: AC
  • Magnetic Tripping Current: 182-182 A
  • [Ith] Conventional Free Air Thermal Current: 13 A IEC 60947-4-1
  • Motor Power Kw: 5.5-5.5 kW 400/415 V AC 50/60 Hz || 7.5-7.5 kW 500 V AC 50/60 Hz || 11-11 kW 690 V AC 50/60 Hz
  • Utilisation Category: AC-3 IEC 60947-4-1
  • Net Weight: 0.96 kg
  • Fixing Mode: 35 mm symmetrical DIN rail clipped || panel screwed with 3 x M4 screws)
  • [Uimp] Rated Impulse Withstand Voltage: 6 kV IEC 60947-2
  • [Ics] Rated Service Short-Circuit Breaking Capacity: 100 % 230/240 V AC 50/60 Hz IEC 60947-2 || 100 % 400/415 V AC 50/60 Hz IEC 60947-2 || 100 % 440 V AC 50/60 Hz IEC 60947-2 || 50 % 500 V AC 50/60 Hz IEC 60947-2 || 50 % 690 V AC 50/60 Hz IEC 60947-2
  • Control Type: rotary handle
  • Power Dissipation Per Pole: 8 W
  • Electrical Durability: 50000 cycles AC-3 415 V In
  • [Ui] Rated Insulation Voltage: 690 V AC 50/60 Hz IEC 60947-2
  • Breaking Capacity: 100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 12 kA Icu 500 V AC 50/60 Hz IEC 60947-2 || 6 kA Icu 690 V AC 50/60 Hz IEC 60947-2
  • Suitability For Isolation: yes IEC 60947-1
  • Thermal Protection Adjustment Range: 9-13 A IEC 60947-4-1
  • Tightening Torque: 5 N.m screw clamp terminal
  • Mechanical Durability: 50000 cycles
  • Poles Description: 3P
  • Color: dark grey
  • Width: 55 mm
  • Depth: 136 mm
  • Network Frequency: 50/60 Hz IEC 60947-4-1

Offer Sustainability

  • Rohs Exemption Information: Yes
  • Mercury Free: Yes
  • Environmental Disclosure: ENVPEP060901
  • Sustainable Offer Status: Green Premium product
  • Reach Regulation: Reference contains Substances of Very High Concern above the threshold
  • California Proposition 65: WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Weee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
  • China Rohs Regulation: Product out of China RoHS scope. Substance declaration for your information.
  • Circularity Profile: ENVEOLI060901
  • Eu Rohs Directive: Compliant

Environment

  • Product Certifications: CCC || UL || CSA || EAC || ATEX || LROS (Lloyds register of shipping) || BV || ABS || DNV-GL || UKCA
  • Ik Degree Of Protection: IK09 enclosure
  • Mechanical Robustness: shocks 15 Gn for 11 ms contactor open || shocks 30 Gn for 11 ms contactor closed || vibrations 4 Gn, 5…300 Hz
  • Ambient Air Temperature For Operation: -20-60 C
  • Standards: EN/IEC 60947-2 || EN/IEC 60947-4-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1
  • Climatic Withstand: IACS E10
  • Ambient Air Temperature For Storage: -40-80 C
  • Ip Degree Of Protection: IP20 IEC 60529
  • Operating Altitude: 9842.52 ft (3000 m)
  • Fire Resistance: 960 C IEC 60695-2-11

Downloads

Spec Sheet

CAD

GV3P65 WITH ONE EVERLINK CONNECTOR – 3D CAD – GV3P80_2D-top (dxf)
GV3P65 WITH ONE EVERLINK CONNECTOR – 3D CAD – GV3P80_2D-back (dwg)
GV3P65 WITH ONE EVERLINK CONNECTOR – 3D CAD – GV3P80_2D-top (dwg)
GV3P65 WITH ONE EVERLINK CONNECTOR – 3D CAD – GV3P80_2D-right (dxf)
GV3P65 WITH ONE EVERLINK CONNECTOR – 3D CAD – GV3P80_3D-simplified (stp)
GV3P65 WITH ONE EVERLINK CONNECTOR – 3D CAD – GV3P80_2D-left (dxf)
GV3P65 WITH ONE EVERLINK CONNECTOR – 3D CAD – GV3P80_2D-isometric (dxf)
GV3P65 WITH ONE EVERLINK CONNECTOR – 3D CAD – GV3P80_2D-front (dxf)
GV3P65 WITH ONE EVERLINK CONNECTOR – 3D CAD – GV3P80_2D-bottom (dxf)
GV3P65 WITH ONE EVERLINK CONNECTOR – 3D CAD – GV3P80_2D-front (dwg)
GV3P65 WITH ONE EVERLINK CONNECTOR – 3D CAD – GV3P80_2D-bottom (dwg)
GV3P65 WITH ONE EVERLINK CONNECTOR – 3D CAD – GV3P80_2D-back (dxf)
GV3P65 WITH ONE EVERLINK CONNECTOR – 3D CAD – GV3P80_2D-isometric (dwg)
GV3P65 WITH ONE EVERLINK CONNECTOR – 3D CAD – GV3P80_2D-right (dwg)
GV3P65 WITH ONE EVERLINK CONNECTOR – 3D CAD – GV3P80_2D-left (dwg)

Catalog

Altivar 312 Variable Speed Drives Catalog (US 2014) – ATV312eCatalog (pdf)
Digest Catalog 18: Contactors and Starters-IEC (SEP 2022) – 0100CT1901_SEC-18_SEP2022 (pdf)
Discover the catalog for Altivar Machine ATV320 variable speed drive – Catalog+Altivar+Machine+ATV320+variable+speed+drives (pdf)

Brochure

Altivar Outdoor Variable Speed Drives Brochure – Altivar+Outdoor (pdf)

Certificate

EU RO MR Type Approval Certificate_TeSys GV3P13-80&GV3L25-80 – GV3P13_80_GV3L25_80_MRE000000K-rev1 (pdf)
CB_Certificate_TeSys GV3P&GV3L – GV3P-L_Dj_CB-DE1-64059 (pdf)
CSA Certificate_ TeSys GV3P&GV3L – COFC_80115486_EN (pdf)
CQC_Certificate_TeSys GV3P – GV3P_Dijon_CQC2009010307369399 (pdf)
DNV Type approval certificate TeSys GV3P13-80&GV3L25-80 – GV3P13_80_GV3L25_80_TAE0000136-revision2 (pdf)

Technical Drawing

Magnetic motor circuit breaker GV3P GV3L Dimensions – GV3F (dwg)
Magnetic motor circuit breaker GV3P GV3L Dimensions – GV3L (pdf)
Magnetic motor circuit breaker GV3P GV3L Dimensions – GV3L (dxf)
Magnetic motor circuit breaker GV3P GV3L Dimensions – GV3F (pdf)
Magnetic motor circuit breaker GV3P GV3L Dimensions – GV3L (dwg)
Magnetic motor circuit breaker GV3P GV3L Dimensions – GV3F (dxf)

Instruction sheet

GV3 P../L.., GV3 P..6/L..6 – Everlink circuit breaker – Instruction Sheet – 1725608_01A55 (pdf)
GV3 P../L.. – Everlink circuit breaker – Instruction sheet – 1725610_01A55-08 (pdf)
ATV12 Variable Speed Drives Extended Short Circuit Ratings – Instructions – S1A35727+Rev.00 (pdf)

User guide

TeSys Power – Deca Motor Circuit Breakers Frame 3 – Use in Explosive Atmospheres – 1672548-08 (pdf)

Data Bulletin

Motor Control Solutions for the North American Market Data Bulletin – 8536DB0901+R04_23 (pdf)
Variable Frequency Drives and Short-Circuit Current Ratings Data Bulletin – 8800DB1203R01_17 (pdf)

Circularity Profile

Motor circuit breaker,TeSys Deca,3P,48-65A – EoLI_ENVEOLI060901EN_V4_1 (pdf)
End-of-Life Instructions TeSys GV3P – ENVEOLI100417EN_GV3P_20100615 (pdf)

Declaration of conformity

UKCA_Declaration_TeSys_GV3P with ATEX – SC16031602-UK (pdf)
EU Declaration TeSys GV3P with ATEX – EU_DoC_GV3P_SC16031602E (pdf)
CCC Self-declaration_TeSys GV3P – GV3P_Dijon_CCC_SDoc_2020980307005010 (pdf)

Environmental Disclosure

Motor circuit breaker,TeSys Deca,3P,48-65A – Internal+PEP+ENVPEP060901EN_V4_1 (pdf)

Videos

Mounting a GV3 Manual Starter to TeSys D Series Contactor | Schneider Electric Support

Shipping Info Standard Shipping
Free Shipping We offer free shipping on orders over $30. Please check the free - shipping eligibility at checkout.
Delivery Time: It usually takes 3-5 business days for standard shipping. Please note that this is an estimated time frame and may be affected by local holidays, and unforeseen circumstances.