safety controller XPS-MC – 24 V DC – 16 input – 32 LEDs signalling

0 Reviews
$1,675.08 $146.00
200 in stock

Unconditional Satisfaction Guarantee
No Shipping Fees Above 30
2 Months to Decide. Returns Simplified.

Specifications

  • Product Certifications: UL || TV || CSA
  • [Us] Rated Supply Voltage: 24 V DC – 20…20 %
  • Range Of Product: Preventa Safety automation
  • Standards: EN/IEC 61496-1 || EN 574/ISO 13851 || EN 1760-1/ISO 13856-1 || IEC 61508 || EN 954-1/EN/ISO 13849-1 || EN/IEC 60947-5-1 || EN/IEC 60204-1
  • Number Of Inputs: 16
  • Product Or Component Type: configurable safety controller
  • Safety Module Name: XPSMC
  • Type Of Start: configurable
  • Communication Port Protocol: CANopen 1 SUB-D 9-pin male, serial link 20 kbps, 50 kbps, 125 kbps, 250 kbps, 500 kbps, 800 kbps or 1 Mbps || Modbus 1 RJ45, serial link 1200 bps, 2400 bps, 4800 bps, 9600 bps or 19200 bps
  • Safety Use Category: category 4 maximum EN 954-1/EN/ISO 13849-1 || PLE maximum EN/ISO 13849-1 || SIL 3 maximum IEC 61508
  • Safety Level: can reach PL e/category 4 EN 954-1/EN/ISO 13849-1 || can reach SIL 3 IEC 61508

Contractual warranty

  • Warranty: 18 months

Complementary

  • Height: 151.5 mm
  • [Ith] Conventional Free Air Thermal Current: 16 A relay output || 6.5 A static output circuit
  • Mounting Support: mounting plate
  • Output Thermal Current: 4 A for both outputs simultaneously || 6 A for 1 output and 2 A for the other relay output
  • Power Consumption In W: 12 W
  • Minimum Output Voltage: 17 V relay output
  • Response Time: configurable : 20 ms or 30 ms with software XPSMCWIN
  • Data Format: 1 start bit/8 data bits || 1 stop bit even or odd || 2 stop bits without parity || RTU (Remote Terminal Unit) mode
  • Minimum Output Current: 10 mA relay output
  • Associated Fuse Rating: 16 A gL power supply || 4 A gL relay output || 6 A fast blow relay output
  • [Uimp] Rated Impulse Withstand Voltage: 4 kV III IEC 60647-5-1, DIN VDE 0110 part 1
  • Net Weight: 0.82 kg
  • Output Type: 2 relays, 2 NO contacts (4 NO total) || solid state, 6, volt-free
  • [Ui] Rated Insulation Voltage: 300 V 2)IEC 60647-5-1, DIN VDE 0110 part 1
  • Parity: even Modbus || no Modbus || odd Modbus
  • Exchange Size: 14 words
  • Supported Modbus Function: 01 8-bit output data/32-bit input data || 02 32-bit input data/8-bit output data || 03 information and errors
  • Method Of Access: slave
  • Local Signalling: 32 LEDs
  • Number Of Addresses: 1-127 CANopen || 1-247 Modbus
  • Maximum Line Resistance: 100 Ohm <2000 m
  • Input Protection Type: external fuse 16 A
  • Width: 74 mm
  • Depth: 153 mm
  • [Uc] Control Circuit Voltage: 28.8 V
  • Function Of Module: dynamic monitoring of hydraulic valves on linear presses || monitoring safety stop at top dead centre on eccentric press || muting function of light curtains || position selector || safety mat monitoring || safety time delays || shaft/chain breaking monitor || zero speed detection || light curtain monitoring category 4 EN/IEC 61496 || two-hand control category 3 EN 574/ISO 13851 || eccentric press || emergency stop monitoring, with or without time delay, 1 or 2-channel wiring || enabling switch monitoring, 2 or 3 contacts || foot switch monitoring || guard monitoring for injection presses and blowing machines || guard monitoring with 1 or 2 limit switches || hydraulic press || magnetic switch monitoring
  • Synchronisation Time Between Inputs: depending on configuration selected
  • Breaking Capacity: 2 A 24 V static output circuit || 1.5 A 24 V DC-13)50 ms relay output
  • Breaking Capacity: 180 VA holding AC-15 C300 relay output || 1800 VA inrush AC-15 C300 relay output

Offer Sustainability

  • Rohs Exemption Information: Yes
  • Mercury Free: Yes
  • Environmental Disclosure: ENVPEP1406025EN
  • Sustainable Offer Status: Green Premium product
  • Pvc Free: Yes
  • Reach Regulation: Reference contains Substances of Very High Concern above the threshold
  • California Proposition 65: WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Weee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
  • China Rohs Regulation: X
  • Circularity Profile: ENVEOLI1406025EN
  • Eu Rohs Directive: Pro-active compliance (Product out of EU RoHS legal scope)

Environment

  • Ambient Air Temperature For Operation: -10-55 C
  • Ip Degree Of Protection: IP20 conforming to EN/IEC 60529
  • Ambient Air Temperature For Storage: -25-85 C

Downloads

Spec Sheet

CAD

XPSMC16ZC_CAD – XPSMC16ZC_2D+Front+View (dwg)
XPSMC16ZC_CAD – XPSMC16ZC_2D+Front+View (dxf)
XPSMC16ZC_CAD – XPSMC16ZC_2D+Right+Side+View (dxf)
XPSMC16ZC_CAD – XPSMC16ZC_2D+Right+Side+View (dwg)
XPSMC16ZC_CAD – XPSMC16ZC_3D (stp)

User guide

XPSMC Safety Controller, Hardware Manual – 33003275.08 (pdf)
XPSMCWIN Configuration Software for XPSMC Safety Controller – 33003281.06 (pdf)
XPSMC… Changes Made to the User’s Manuel – 33003639 (pdf)

Instruction sheet

XPSMC16 / XPSMC32 Safety controler – N_2A15600 (pdf)

Technical Drawing

XPSMC16ZC_2D_Drwng_PDF – XPSMC16ZC_2D+Sales+Drawing (pdf)

Certificate

Preventa XPS-MC safety controller, Certificate, TUV, Functional Safety – EC_Type_Examination_XPSMC_4420513754308_valid_20270505 (pdf)

Application Notes

Schneider Electric SISTEMA Library – SE_Sistema_2022_11_29.zip

Software – Hotfix

Patch for XPSMCWIN – XPSMCWIN_2.xx_to_2.4.0_patch.exe

Software – Demos & Trial

XPSMCWIN – XPSMCWin+2.4.0+Demo+Setup.exe

Circularity Profile

XPS MC… Safety Relay, Product End-of-Life Instructions – ENVEOLI111231EN_V0 (pdf)
XPSMC… Preventa Safety Controller, Product End-of-Life Instructions – ENVEOLI1406025EN_V2 (pdf)

System user guide

Modicon M340, CANopen, Altivar, Lexium, TeSysU and Preventa – m340_canopen_altivar_lexium_tesysu_preventa_en (pdf)

Catalog

Catalog safety configurable controllers Preventa XPSMC- January 2015 – Catalog+Safety+configurable+controllers+Preventa+XPSMC-+January+2015 (pdf)

Environmental Disclosure

XPSMC… Preventa Safety Controller, Product Environmental Profile – ENVPEP1406025EN_V2 (pdf)

Declaration of conformity

Preventa XPSMC, Declaration of Conformity, UKCA, Schneider Electric – UK_NNZ1353201.00_UK-DeclarationOfconformity_XPSMC_signed (pdf)
Preventa XPSMC, Declaration of Conformity, EU CE, Schneider Electric, Safety – NNZ1353201.01_DeclarationOfconformity_XPSMC_signed (pdf)

Shipping Info Standard Shipping
Free Shipping We offer free shipping on orders over $30. Please check the free - shipping eligibility at checkout.
Delivery Time: It usually takes 3-5 business days for standard shipping. Please note that this is an estimated time frame and may be affected by local holidays, and unforeseen circumstances.