product-details

IEC contactor, TeSys Deca, nonreversing, 150A, 100HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 208VAC 50/60Hz coil, open

0 Reviews
$742.29 $147.00
200 in stock

Unconditional Satisfaction Guarantee
No Shipping Fees Above 30
2 Months to Decide. Returns Simplified.

Specifications

  • [Uc] Control Circuit Voltage: 208 V AC 50/60 Hz
  • [Ue] Rated Operational Voltage: power circuit <= 1000 V AC 25…400 Hz || power circuit <= 300 V DC
  • Range Of Product: TeSys Deca
  • Contactor Application: resistive load || motor control
  • Product Or Component Type: contactor
  • Range: TeSys
  • Utilisation Category: AC-1 || AC-4 || AC-3 || AC-3e
  • [Ie] Rated Operational Current: 200 A 60 C) <= 440 V AC AC-1 power circuit || 150 A 60 C) <= 440 V AC AC-3 power circuit || 150 A 60 C) <= 440 V AC AC-3e power circuit
  • Poles Description: 3P
  • Device Short Name: LC1D

Contractual warranty

  • Warranty: 18 months

Complementary

  • Non-Overlap Time: 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
  • Minimum Switching Current: 5 mA signalling circuit
  • Power Dissipation Per Pole: 24 W AC-1 || 13.5 W AC-3 || 13.5 W AC-3e
  • Average Impedance: 0.6 mOhm – Ith 200 A 50 Hz power circuit
  • Auxiliary Contact Composition: 1 NO + 1 NC
  • [Ith] Conventional Free Air Thermal Current: 200 A 60 C power circuit
  • Control Circuit Voltage Limits: 0.3…0.5 Uc -40-70 C drop-out AC 50/60 Hz || 0.8…1.15 Uc -40-55 C operational AC 50/60 Hz || 1…1.15 Uc 55-70 C operational AC 50/60 Hz
  • Mounting Support: rail || plate
  • Contact Compatibility: M13
  • Control Circuit Type: AC 50/60 Hz
  • Safety Reliability Level: B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
  • Pollution Degree: 3
  • Insulation Resistance: > 10 MOhm signalling circuit
  • Rated Breaking Capacity: 1400 A 440 V power circuit IEC 60947
  • Irms Rated Making Capacity: 140 A AC signalling circuit IEC 60947-5-1 || 250 A DC signalling circuit IEC 60947-5-1 || 1660 A 440 V power circuit IEC 60947
  • Associated Fuse Rating: 10 A gG signalling circuit IEC 60947-5-1 || 315 A gG <= 690 V type 1 power circuit || 250 A gG <= 690 V type 2 power circuit
  • [Uimp] Rated Impulse Withstand Voltage: 8 kV IEC 60947
  • Inrush Power In Va: 280-350 VA 60 Hz 0.9 20 C) || 280-350 VA 50 Hz 0.9 20 C)
  • Pole Contact Composition: 3 NO
  • Connections – Terminals: control circuit screw clamp terminals 2 1-2.5 mm flexible with cable end || control circuit screw clamp terminals 1 1-2.5 mm flexible with cable end || control circuit screw clamp terminals 1 1-2.5 mm flexible without cable end || control circuit screw clamp terminals 2 1-2.5 mm flexible without cable end || control circuit screw clamp terminals 1 1-2.5 mm solid without cable end || control circuit screw clamp terminals 2 1-2.5 mm solid without cable end || power circuit connector 1 10-120 mm flexible without cable end || power circuit connector 2 10-50 mm flexible without cable end || power circuit connector 1 10-120 mm flexible with cable end || power circuit connector 2 10-50 mm flexible with cable end || power circuit connector 1 10-120 mm solid without cable end || power circuit connector 2 10-50 mm solid without cable end
  • Coil Technology: built-in bidirectional peak limiting diode suppressor
  • Operating Time: 20…35 ms closing || 40…75 ms opening
  • Minimum Switching Voltage: 17 V signalling circuit
  • Maximum Operating Rate: 1200 cyc/h 60 C
  • Signalling Circuit Frequency: 25…400 Hz
  • Tightening Torque: control circuit 1.2 N.m screw clamp terminals flat 6 mm || control circuit 1.2 N.m screw clamp terminals Philips No 2 || power circuit 12 N.m connector hexagonal 4 mm || control circuit 1.2 N.m screw clamp terminals pozidriv No 2
  • Electrical Durability: 0.85 Mcycles 150 A AC-3 <= 440 V || 1 Mcycles 200 A AC-1 <= 440 V || 0.85 Mcycles 150 A AC-3e <= 440 V
  • Mechanical Durability: 8 Mcycles
  • Auxiliary Contacts Type: mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
  • Compatibility Code: LC1D
  • Hold-In Power Consumption In Va: 2-18 VA 60 Hz 0.9 20 C) || 2-18 VA 50 Hz 0.9 20 C)
  • Overvoltage Category: III
  • Maximum Horse Power Rating: 40 hp 200/208 V at AC 50/60 Hz for 3 phase || 50 hp 230/240 V at AC 50/60 Hz for 3 phase || 100 hp 460/480 V at AC 50/60 Hz for 3 phase || 125 hp 575/600 V at AC 50/60 Hz for 3 phase
  • Motor Power Kw: 40 kW 220…230 V AC 50/60 Hz AC-3) || 75 kW 380…400 V AC 50/60 Hz AC-3) || 80 kW 415…440 V AC 50/60 Hz AC-3) || 90 kW 500 V AC 50/60 Hz AC-3) || 100 kW 660…690 V AC 50/60 Hz AC-3) || 75 kW 1000 V AC 50/60 Hz AC-3) || 22 kW 400 V AC 50/60 Hz AC-4) || 40 kW 220…230 V AC 50/60 Hz AC-3e) || 75 kW 380…400 V AC 50/60 Hz AC-3e) || 80 kW 415…440 V AC 50/60 Hz AC-3e) || 90 kW 500 V AC 50/60 Hz AC-3e) || 100 kW 660…690 V AC 50/60 Hz AC-3e) || 75 kW 1000 V AC 50/60 Hz AC-3e)
  • [Ui] Rated Insulation Voltage: power circuit 600 V CSA || power circuit 600 V UL || power circuit 1000 V IEC 60947-4-1 || signalling circuit 690 V IEC 60947-1 || signalling circuit 600 V CSA || signalling circuit 600 V UL
  • [Icw] Rated Short-Time Withstand Current: 250 A 40 C – 10 min power circuit || 580 A 40 C – 1 min power circuit || 1200 A 40 C – 10 s power circuit || 1400 A 40 C – 1 s power circuit || 100 A – 1 s signalling circuit || 120 A – 500 ms signalling circuit || 140 A – 100 ms signalling circuit
  • Heat Dissipation: 3-4.5 W 50/60 Hz
  • Protective Cover: with

Offer Sustainability

  • Rohs Exemption Information: Yes
  • Mercury Free: Yes
  • Environmental Disclosure: ENVPEP060301EN
  • Sustainable Offer Status: Green Premium product
  • Pvc Free: Yes
  • Reach Regulation: Reference contains Substances of Very High Concern above the threshold
  • California Proposition 65: WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Weee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
  • China Rohs Regulation: Product out of China RoHS scope. Substance declaration for your information.
  • Circularity Profile: ENVEOLI100405
  • Eu Rohs Directive: Compliant

Environment

  • Product Certifications: GL || GOST || DNV || LROS (Lloyds register of shipping) || CSA || BV || RINA || CCC || UL || UKCA || CE
  • Height: 158 mm
  • Standards: CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508
  • Climatic Withstand: IACS E10 exposure to damp heat
  • Net Weight: 2.5 kg
  • Flame Retardance: V1 conforming to UL 94
  • Protective Treatment: THIEC 60068-2-30
  • Ip Degree Of Protection: IP20 front face IEC 60529
  • Mechanical Robustness: vibrations contactor open 2 Gn, 5…300 Hz) || vibrations contactor closed 4 Gn, 5…300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 6 Gn for 11 ms)
  • Operating Altitude: 0…9842.52 ft (0…3000 m)
  • Fire Resistance: 850 C IEC 60695-2-1
  • Width: 120 mm
  • Depth: 136 mm
  • Permissible Ambient Air Temperature Around The Device: -40-60 C || 60-70 C with derating

Downloads

Spec Sheet

CAD

LC1D150LE7_CAD_DOC – LC1D150LE7_2D+Front+View (dxf)
LC1D150LE7_CAD_DOC – LC1D150LE7_2D+Right+Side+View (dxf)
Tesys D Contactor D115 3P – HORUS_3P_W_AUX (stp)
LC1D150LE7_CAD_DOC – LC1D150LE7_3D (stp)
LC1D150LE7_CAD_DOC – LC1D150LE7_2D+Right+Side+View (dwg)
LC1D150LE7_CAD_DOC – LC1D150LE7_2D+Front+View (dwg)

Brochure

Square D Model 6 Intelligent Motor Control Centers Brochure – 8998BR0001 (pdf)
Industrial Automation and Control Product Lines Brochure – 998-20256927_2019_Line_Card_GM (pdf)
TeSys Refresh Informational Guide – Brochure – 998-20803955_GMA-US (pdf)

Certificate

DNV Type Approval Certificate_TeSys D_LC1D115-150&LC2D115-150 – LC.D115-150_TAE000011A-revision1_DNV (pdf)
UL_Certificate_TeSys D_LC1D115-150&LC2D115-150 – E48539-19971110-CertificateofCompliance (pdf)
BV Type Approval Certificate_TeSys D_LC1D115-150&LC2D115-150 – LC.D115-150_22615_C0+BV (pdf)
CB_Certificate_TeSys D_LC1D115-150&LC2D115-150 – LC.D115-150_Pisek_HU-004003 (pdf)
CSA Certificate_ TeSys D_LC1D115-150&LC2D115-150 – COFC_80098990_EN (pdf)
RINA Type Approval Certificate_TeSys D_LC1D115-150&LC2D115-150 – LC.D115-150_ELE058320CS (pdf)
ABS Type Approval Certificate_TeSys D_LC1D115-150&LC2D115-150 – LC.D115-150_Certificate+No.22-2253899-PDA_ABS (pdf)

Circularity Profile

End-of-Life Instructions TeSys LC1D115 – ENVEOLI100405EN_LC1D115_20100615 (pdf)
TeSys D LC1 D115-D150 – EoLI_ENVEOLI100405EN_1 (pdf)

Technical Drawing

Technical drawing for LC1D150LE7_CAD_DOC – LC1D150LE7_2D+Right+Side+View (dxf)
Technical drawing for LC1D150LE7_CAD_DOC – LC1D150LE7_2D+Front+View (dxf)
LC1D150LE7_2DSalesDrawing_PDF – LC1D150LE7_2D+Sales+Drawing (pdf)
Technical drawing for LC1D150LE7_CAD_DOC – LC1D150LE7_2D+Right+Side+View (dwg)
Technical drawing for LC1D150LE7_CAD_DOC – LC1D150LE7_2D+Front+View (dwg)

Environmental Disclosure

PEP – TeSys D LC1D115 to D150 contactors – PEP+ecopassport+SCHN-2015-075-EN_1 (pdf)

Declaration of conformity

EU Declaration TeSys D_LC1D115-150 & LC2D115-150 – PP_EU_Doc_LC.D115-150_SC16040602E.docx (pdf)
UKCA Declaration TeSysD_LC.D115-150 – UK_Doc_LC.D115-150_SC16040602A-UK.docx (pdf)

Instruction sheet

LC1/LC2 D115 D150 Contactors / Reversing contactors – Instruction Sheet – W915113010123-15 (pdf)

Data Bulletin

Motor Control Solutions for the North American Market Data Bulletin – 8536DB0901+R04_23 (pdf)

Videos

Mounting & Unmounting TeSys D Contactors to DIN Rails | Schneider Electric Support Locating the TeSys D Line IEC Contactor Model Number | Schneider Electric Support Installing & Removing Mechanical and Electrical Interlock on TeSys D | Schneider Electric Support Removing Auxiliary Contact Block from TeSys D Series Contactor | Schneider Electric Support Mounting Auxiliary Contact Block to TeSys D Series Contactor | Schneider Electric Support

Shipping Info Standard Shipping
Free Shipping We offer free shipping on orders over $30. Please check the free - shipping eligibility at checkout.
Delivery Time: It usually takes 3-5 business days for standard shipping. Please note that this is an estimated time frame and may be affected by local holidays, and unforeseen circumstances.