Specifications

  • Thermal Protection Adjustment Range: 1.6-8 A
  • Power Consumption In W: 300 mW
  • Relay Application: motor protection
  • Product Or Component Type: electronic thermal overload relay
  • Product Name: TeSys LRD
  • Thermal Overload Class: class 530
  • Range: TeSys
  • Mounting Support: under contactor || plate, with specific accessories || rail, with specific accessories
  • Product Compatibility: LC1D12 || LC1D32 || LC1D38 || LC1D09 || LC1D25 || LC1D18
  • Device Short Name: LR9D

Complementary

  • Time Range: 1.5…4 min – automatic reset time
  • Height: 72.5 mm
  • [Ith] Conventional Free Air Thermal Current: 5 A signalling circuit
  • Tightening Torque: control circuit 0.8 N.m screw clamp terminals || power circuit 3.1 N.m screw clamp terminals
  • Phase Failure Sensitivity: phase difference > 40% 3-3 s IEC 60947-4-1
  • [Ue] Rated Operational Voltage: 690 V power circuit || 660 V signalling circuit
  • Electromagnetic Compatibility: surge withstand 2 kV common mode IEC 61000-4-5 || resistance to electrostatic discharge 8 kV IEC 61000-4-2 || immunity to radiated radio-electrical interference 10 V/m IEC 61000-4-3 || immunity to fast transients 2 kV IEC 61000-4-4
  • Associated Fuse Rating: 5 A gG signalling circuit || 5 A BS signalling circuit
  • Net Weight: 0.18 kg
  • [Uimp] Rated Impulse Withstand Voltage: 6 kV
  • Connections – Terminals: control circuit screw clamp terminals 1 2.5-2.5 mm solid or flexible – without cable end || power circuit screw clamp terminals 1 16-16 mm solid or flexible – without cable end
  • [Ui] Rated Insulation Voltage: power circuit 1000 V || signalling circuit 690 V
  • Tripping Threshold: 1.25 In IEC 60947-4-1
  • Control Type: Red push-button stop and manual reset || White 2 microswitches adjustable trip class || Red knob automatic reset || White dial full-load current adjustment
  • Width: 45 mm
  • Depth: 79.9 mm

Offer Sustainability

  • Rohs Exemption Information: Yes
  • Mercury Free: Yes
  • Environmental Disclosure: ENVPEP1502001EN
  • Sustainable Offer Status: Green Premium product
  • Reach Regulation: Reference contains Substances of Very High Concern above the threshold
  • California Proposition 65: WARNING: Cancer and Reproductive Harm – www.P65Warnings.ca.gov
  • Reach Free Of Svhc: Yes
  • Weee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
  • China Rohs Regulation: Product out of China RoHS scope. Substance declaration for your information.
  • Circularity Profile: ENVEOLI1502001EN
  • Eu Rohs Directive: Compliant

Environment

  • Product Certifications: IECEE CB Scheme || UL || CSA || CCC
  • Mechanical Robustness: vibrations 10…150 Hz6 Gn IEC 60068-2-6 || shocks 11 ms15 gn IEC 60068-2-7
  • Standards: EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || UL 60947-5-1 || CSA C22.2 No 60947-4-1 || CSA C22.2 No 60947-5-1 || GB/T 14048.4 || GB/T 14048.5
  • Ambient Air Temperature For Operation: -25-70 C IEC 60255-8
  • Dielectric Strength: 6 kV 50 Hz IEC 60255-5
  • Ambient Air Temperature For Storage: -55-80 C
  • Ip Degree Of Protection: IP20 front face IEC 60529
  • Operating Altitude: 6561.68 ft (2000 m) without derating

Downloads

Spec Sheet

Catalog

Digest Catalog 16: NEMA and Definite Purpose Contactors and Starters (SEP 2022) – 0100CT1901_SEC-16_SEP2022 (pdf)
Industrial Control Panel Solutions Catalog – 8800CT1801 (pdf)
Digest Catalog 18: Contactors and Starters-IEC (SEP 2022) – 0100CT1901_SEC-18_SEP2022 (pdf)
TeSys Catalogue – 2022 – Chapter B11 – Overload relays TeSys LRK, Deca, Giga, RM1, LT3 – B11+-+Overload+relays_EN+(web) (pdf)

Brochure

New TeSys LR9D Electronic Overload Relays – TESYSLR9D+3-16 (pdf)

Certificate

TeSys LR9, Certificate, ABS – LR9D-F_ABS_2017+Marine+Certificate (pdf)

CAD

TeSys LR.D – Electronic thermal overload protection TeSys LR9D 0.1… 32 Amps – 3D CAD – MCADPD0004548_2D-bottom (dwg)
Electronic thermal overload protection TeSys LR9D 0.1… 32 Amps with accessorie LAD7B205 – SB111472_3D-Simplified (stp)
TeSys LR.D – Electronic thermal overload protection TeSys LR9D 0.1… 32 Amps – 3D CAD – MCADPD0004548_2D-top (dwg)
TeSys LR.D – Electronic thermal overload protection TeSys LR9D 0.1… 32 Amps – 3D CAD – MCADPD0004548_2D-bottom (dxf)
TeSys LR.D – Electronic thermal overload protection TeSys LR9D 0.1… 32 Amps – 3D CAD – MCADPD0004548_2D-isometric (dwg)
TeSys LR.D – Electronic thermal overload protection TeSys LR9D 0.1… 32 Amps – 3D CAD – MCADPD0004548_2D-isometric (dxf)
TeSys LR.D – Electronic thermal overload protection TeSys LR9D 0.1… 32 Amps – 3D CAD – MCADPD0004548_3D-simplified (stp)
TeSys LR.D – Electronic thermal overload protection TeSys LR9D 0.1… 32 Amps – 3D CAD – MCADPD0004548 (pdf)
TeSys LR.D – Electronic thermal overload protection TeSys LR9D 0.1… 32 Amps – 3D CAD – MCADPD0004548_2D-top (dxf)
TeSys LR.D – Electronic thermal overload protection TeSys LR9D 0.1… 32 Amps – 3D CAD – MCADPD0004548_2D-back (dwg)
Electronic thermal overload protection TeSys LR9D 0.1… 32 Amps with accessorie LAD7B205 – SB111472_3D-Simplified (pdf)
TeSys LR.D – Electronic thermal overload protection TeSys LR9D 0.1… 32 Amps – 3D CAD – MCADPD0004548_2D-right (dwg)
TeSys LR.D – Electronic thermal overload protection TeSys LR9D 0.1… 32 Amps – 3D CAD – MCADPD0004548_2D-left (dwg)
TeSys LR.D – Electronic thermal overload protection TeSys LR9D 0.1… 32 Amps – 3D CAD – MCADPD0004548_2D-back (dxf)
TeSys LR.D – Electronic thermal overload protection TeSys LR9D 0.1… 32 Amps – 3D CAD – MCADPD0004548_2D-right (dxf)
TeSys LR.D – Electronic thermal overload protection TeSys LR9D 0.1… 32 Amps – 3D CAD – MCADPD0004548_2D-left (dxf)
TeSys LR.D – Electronic thermal overload protection TeSys LR9D 0.1… 32 Amps – 3D CAD – MCADPD0004548_2D-front (dwg)
TeSys LR.D – Electronic thermal overload protection TeSys LR9D 0.1… 32 Amps – 3D CAD – MCADPD0004548_2D-front (dxf)

Instruction sheet

TeSys LR9D, electronic thermal overload relays – NHA45219-01 (pdf)
Motor Logic Solid-State Overload Relay Installation Instructions – 30072-452-39+final (pdf)
TeSys LR9D/LR9F Overload Relays Instruction Bulletin – LR9D+Instruction+sheet (pdf)

Technical Drawing

CAD drawing for TeSys LR9D 0.1… 32 Amps – SB111472_3D-Simplified (pdf)
CAD drawing for Electronic thermal overload protection TeSys LR9D 0.1… 32 Amps – SB111470_3D-Simplified (pdf)

Environmental Disclosure

PEP_TeSys LR9D Solid State Overload Relay – ENVPEP1502001EN_V2 (pdf)

Declaration of conformity

EU Declaration SC16040807B TeSys LR9D-LR9D110s-LAD7B205 – SC16040807B (pdf)

Circularity Profile

Eoli_Contactors, TeSys LRD – electronic thermal overload relay – 3P – 6.4…32 A – ENVEOLI1502001EN_V2 (pdf)

Data Bulletin

Motor Control Solutions for the North American Market Data Bulletin – 8536DB0901+R04_23 (pdf)

Shipping Info Standard Shipping
Free Shipping We offer free shipping on orders over $30. Please check the free - shipping eligibility at checkout.
Delivery Time: It usually takes 3-5 business days for standard shipping. Please note that this is an estimated time frame and may be affected by local holidays, and unforeseen circumstances.