Specifications

  • Product Or Component Type: motor circuit breaker
  • Product Name: TeSys GV2 || TeSys Deca
  • Range: TeSys Deca
  • Device Application: motor protection
  • Device Short Name: GV2ME
  • Trip Unit Technology: thermal-magnetic

Contractual warranty

  • Warranty: 18 months

Complementary

  • Line Rated Current: 23 A
  • [Ue] Rated Operational Voltage: 690 V AC 50/60 Hz IEC 60947-2
  • Height: 89 mm
  • Phase Failure Sensitivity: yes IEC 60947-4-1
  • Rated Duty: continuous IEC 60947-4-1
  • Network Type: AC
  • Magnetic Tripping Current: 327-327 A
  • [Ith] Conventional Free Air Thermal Current: 23 A IEC 60947-4-1
  • Motor Power Kw: 9-9 kW 400/415 V AC 50/60 Hz || 11-11 kW 500 V AC 50/60 Hz || 18.5-18.5 kW 690 V AC 50/60 Hz
  • Utilisation Category: category A IEC 60947-2 || AC-3 IEC 60947-4-1
  • Net Weight: 0.26 kg
  • Fixing Mode: 35 mm symmetrical DIN rail clipped || panel screwed with adaptor plate)
  • [Uimp] Rated Impulse Withstand Voltage: 6 kV IEC 60947-2
  • [Ics] Rated Service Short-Circuit Breaking Capacity: 100 % 230/240 V AC 50/60 Hz IEC 60947-2 || 40 % 400/415 V AC 50/60 Hz IEC 60947-2 || 50 % 440 V AC 50/60 Hz IEC 60947-2 || 75 % 500 V AC 50/60 Hz IEC 60947-2 || 75 % 690 V AC 50/60 Hz IEC 60947-2
  • Control Type: push-button
  • Power Dissipation Per Pole: 2.5 W
  • Electrical Durability: 100000 cycles AC-3 415 V In
  • [Ui] Rated Insulation Voltage: 690 V AC 50/60 Hz IEC 60947-2
  • Breaking Capacity: 50 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2 || 15 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 || 6 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 4 kA Icu 500 V AC 50/60 Hz IEC 60947-2 || 3 kA Icu 690 V AC 50/60 Hz IEC 60947-2
  • Suitability For Isolation: yes IEC 60947-1 7-1-6
  • Thermal Protection Adjustment Range: 17-23 A IEC 60947-4-1
  • Tightening Torque: 1.7 N.m screw clamp terminal
  • Mechanical Durability: 100000 cycles
  • Poles Description: 3P
  • Color: dark grey
  • Width: 45 mm
  • Depth: 78.5 mm
  • Network Frequency: 50/60 Hz IEC 60947-4-1

Offer Sustainability

  • Rohs Exemption Information: Yes
  • Mercury Free: Yes
  • Environmental Disclosure: ENVPEP121004
  • Sustainable Offer Status: Green Premium product
  • Reach Regulation: Reference contains Substances of Very High Concern above the threshold
  • California Proposition 65: WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Weee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
  • China Rohs Regulation: Product out of China RoHS scope. Substance declaration for your information.
  • Circularity Profile: ENVEOLI121004
  • Eu Rohs Directive: Compliant

Environment

  • Product Certifications: CCC || UL || CSA || EAC || ATEX || LROS (Lloyds register of shipping) || BV || RINA || DNV-GL || UKCA
  • Ik Degree Of Protection: IK04
  • Mechanical Robustness: shocks 30 Gn for 11 ms || vibrations 5 Gn, 5…150 Hz
  • Ambient Air Temperature For Operation: -20-60 C
  • Standards: EN/IEC 60947-2 || EN/IEC 60947-4-1
  • Climatic Withstand: IACS E10
  • Ambient Air Temperature For Storage: -40-80 C
  • Ip Degree Of Protection: IP20 IEC 60529
  • Operating Altitude: 6561.68 ft (2000 m)
  • Fire Resistance: 960 C IEC 60695-2-11

Downloads

Spec Sheet

CAD

TeSys_GV2ME MOTOR CB THERM/MAG 4-6.3A ROCKER – 3D CAD – MCADPD0003997_2D-back (dwg)
TeSys_GV2ME MOTOR CB THERM/MAG 4-6.3A ROCKER – 3D CAD – MCADPD0003997_3D-simplified (stp)
Manual Starter and Protector, 0.10-32A, 3 Pole – GV2M-0-OD (dwg)
TeSys_GV2ME MOTOR CB THERM/MAG 4-6.3A ROCKER – 3D CAD – MCADPD0003997_2D-left (dxf)
TeSys_GV2ME MOTOR CB THERM/MAG 4-6.3A ROCKER – 3D CAD – MCADPD0003997_2D-bottom (dwg)
TeSys_GV2ME MOTOR CB THERM/MAG 4-6.3A ROCKER – 3D CAD – MCADPD0003997_2D-front (dxf)
TeSys_GV2ME MOTOR CB THERM/MAG 4-6.3A ROCKER – 3D CAD – MCADPD0003997_2D-top (dwg)
TeSys_GV2ME MOTOR CB THERM/MAG 4-6.3A ROCKER – 3D CAD – MCADPD0003997_2D-right (dxf)
TeSys_GV2ME MOTOR CB THERM/MAG 4-6.3A ROCKER – 3D CAD – MCADPD0003997_2D-top (dxf)
TeSys_GV2ME MOTOR CB THERM/MAG 4-6.3A ROCKER – 3D CAD – MCADPD0003997_2D-front (dwg)
TeSys_GV2ME MOTOR CB THERM/MAG 4-6.3A ROCKER – 3D CAD – MCADPD0003997_2D-back (dxf)
TeSys_GV2ME MOTOR CB THERM/MAG 4-6.3A ROCKER – 3D CAD – MCADPD0003997_2D-left (dwg)
TeSys_GV2ME MOTOR CB THERM/MAG 4-6.3A ROCKER – 3D CAD – MCADPD0003997 (pdf)
TeSys_GV2ME MOTOR CB THERM/MAG 4-6.3A ROCKER – 3D CAD – MCADPD0003997_2D-isometric (dxf)
TeSys_GV2ME MOTOR CB THERM/MAG 4-6.3A ROCKER – 3D CAD – MCADPD0003997_2D-right (dwg)
TeSys_GV2ME MOTOR CB THERM/MAG 4-6.3A ROCKER – 3D CAD – MCADPD0003997_2D-isometric (dwg)
TeSys_GV2ME MOTOR CB THERM/MAG 4-6.3A ROCKER – 3D CAD – MCADPD0003997_2D-bottom (dxf)

Catalog

Automation and Control Essentials Catalog 2023-EN – DIA5ED2170101EN_v7_Web (pdf)
Digest Catalog 18: Contactors and Starters-IEC (SEP 2022) – 0100CT1901_SEC-18_SEP2022 (pdf)
Altistart 01 Soft Starters Catalog – ATS01eCatalog (pdf)
TeSys catalogue 2021 – Chapter A1 Enclosed starters – A1+-+Enclosed+starters_EN+(web) (pdf)

Instruction sheet

GV2 ME.. Motor circuit-breakers – IS on the box – Instruction Sheet – 1645571_01A55 (pdf)
LAD912GV Star delta kit – 0381869_01A55_04 (pdf)

Certificate

UL_Certificate_TeSys GV2ME&GV2RT&GV2P&GV2L&GV2LE – E89451-19930716-CertificateofCompliance (pdf)
CB_Certificate_TeSys GV2ME&GV2RT&GV2P&GV2L&GV2LE – CB+cert_GV2_Dijon_Bangpoo_CN55413-M1 (pdf)
CQC_Certificate_TeSys GV2ME&GV2RT&GV2P&GV2L&GV2LE_France – GV2-Dijon_CQC2003010307059256 (pdf)
CQC_Certificate_TeSys GV2ME&GV2P&GV2L_Thailand – GV2-Bangpoo_CQC2007010307236560 (pdf)
DNV-GL Type Approval Certificate TeSys GV2ME&GV2P&GV2L – GV2+-+TAE0000202-revision1 (pdf)
BV Type Approval Certificate_TeSys GV2ME&GV2RT&GV2P&GV2L&GV2LE – GV2P-L-M-ME-RT_GV2A_05570_F0 (pdf)
CSA Certificate_TeSys GV2ME&GV2RT&GV2P&GV2MC&GV2MP and GV2P Type E & GV2P combined with LC1D09-38 type F – COFC_80115485_EN (pdf)
RINA Type Approval Certificate_TeSys GV2ME&GV2RT&GV2P&GV2L&GV2LE – RINA_GV2_ELE373320CS (pdf)
ATEX Certificate TeSys GV2ME&GV2P – GV2ME-P_06ATEX0035X.02 (pdf)

Technical Drawing

Thermal magnetic circuit breaker GV2ME for connection by screw clamp terminals. Dimensions – gv2meF (pdf)
Thermal magnetic motor circuit breaker Pushbutton control Dimensions – B-GV2ME01-to-ME32_CAD2D-MECHANICAL_FRONT (dwg)
Manual StarterAnd Protector 010-32A 3P Technical drawings – GV2M-0-OD (pdf)
Thermal magnetic circuit-breakers with screw clA terminal Technical drawings – GV2ME01R (pdf)
motor circuit breaker 25 A Dimensions – A-GV2ME01-to-ME32_CAD2D-MECHANICAL_FRONT (pdf)
Thermal magnetic circuit-breakers with screw clamp terminal – GV2ME01F (dwg)
Manual StarterAnd Protector 010-32A 3P Technical drawings – GV2M-0-OD (dwg)
Thermal magnetic circuit breaker GV2ME for connection by screw clamp terminals. Dimensions – gv2meR (dxf)
Thermal magnetic motor circuit breaker Pushbutton control Dimensions – B-GV2ME01-to-ME32_CAD2D-MECHANICAL_FRONT (pdf)
motor circuit breaker 25 A Dimensions – A-GV2ME01-to-ME32_CAD2D-MECHANICAL_FRONT (dxf)
Thermal magnetic circuit breaker GV2ME for connection by screw clamp terminals. Dimensions – gv2meR (dwg)
Thermal magnetic circuit-breakers with screw clA terminal Technical drawings – GV2ME01R (dxf)
Thermal magnetic circuit breaker GV2ME for connection by screw clamp terminals. Dimensions – gv2meR (pdf)
motor circuit breaker 25 A Dimensions – A-GV2ME01-to-ME32_CAD2D-MECHANICAL_FRONT (dwg)
Thermal magnetic motor circuit breaker Pushbutton control Dimensions – B-GV2ME01-to-ME32_CAD2D-MECHANICAL_FRONT (dxf)
Thermal magnetic circuit breaker GV2ME for connection by screw clamp terminals. Dimensions – gv2meF (dxf)
Thermal magnetic circuit-breakers with screw clamp terminal – GV2ME01F (dxf)
Thermal magnetic circuit breaker GV2ME for connection by screw clamp terminals. Dimensions – gv2meF (dwg)
Thermal magnetic circuit-breakers with screw clA terminal Technical drawings – GV2ME01R (dwg)

User guide

TeSys Power – Deca Motor Circuit Breakers Frame 2 – Use in Explosive Atmospheres – 1672546-07 (pdf)

Circularity Profile

TeSys GV2 motor circuit breaker – EoLI_ENVEOLI121004EN_V3_1 (pdf)

Environmental Disclosure

TeSys GV2 motor circuit breaker – Internal+PEP+ENVPEP121004EN_V3_1 (pdf)

Technical illustration

Illustration: Dimensions Drawing for GV2ME01-32 Motor Circuit Protectors – GV2M-0-OD_TI_DIM.svg

Declaration of conformity

CCC Self-declaration_TeSys GV2ME&GV2RT&GV2P&GV2L&GV2LE_France – GV2-Dijon_CCC-SDoc_2020980307004793 (pdf)
UKCA Declaration TeSys GV_GV2ME_GV2P with ATEX – UK_UKCA_declaration-NoSC16031601-UK_TeSysGV2ME_GV2P.docx (pdf)
CCC Self-declaration_TeSys GV2ME&GV2P&GV2L_Thailand – GV2-Bangpoo_CCC-SDoc_2020980307004483 (pdf)
EU Declaration TeSys GV2ME&GV2RT&GV2P&GV2L&GV2LE – EU_DoC_GV2ME%26GV2RT%26GV2P%26GV2L%26GV2LE_SC16041104G (pdf)
EU Declaration TeSys GV2ME & GV2P with ATEX – EU_DoC_GV2ME_GV2P+with+ATEX_SC16031601E (pdf)
UKCA Declaration TeSys GV2ME&GV2RT&GV2P&GV2L&GV2LE – UKCA_Doc_SC16041104-UK-GV2L-RT (pdf)

Data Bulletin

Motor Control Solutions for the North American Market Data Bulletin – 8536DB0901+R04_23 (pdf)

Videos

Mounting & Unmounting TeSys GV Manual Starter to DIN Rails | Schneider Electric Support Installing Auxiliary Contacts to TeSys GV2 IEC Manual Starters | Schneider Electric Support

Shipping Info Standard Shipping
Free Shipping We offer free shipping on orders over $30. Please check the free - shipping eligibility at checkout.
Delivery Time: It usually takes 3-5 business days for standard shipping. Please note that this is an estimated time frame and may be affected by local holidays, and unforeseen circumstances.