Specifications

  • Product Or Component Type: motor circuit breaker
  • Product Name: TeSys GV2 || TeSys Deca
  • Range: TeSys Deca
  • Device Application: motor protection || motor
  • Device Short Name: GV2RT
  • Trip Unit Technology: thermal-magnetic

Contractual warranty

  • Warranty: 18 months

Complementary

  • Line Rated Current: 2.5 A
  • [Ue] Rated Operational Voltage: 690 V AC 50/60 Hz IEC 60947-2
  • Height: 89 mm
  • Rated Duty: continuous IEC 60947-4-1
  • Network Type: AC
  • Magnetic Tripping Current: 51-51 A
  • [Ith] Conventional Free Air Thermal Current: 2.5 A IEC 60947-4-1
  • Motor Power Kw: 0.37-0.37 kW 220/230 V AC 50/60 Hz motor protection high peak current || 0.75-0.75 kW 400/415 V AC 50/60 Hz motor protection high peak current || 0.75-0.75 kW 440 V AC 50/60 Hz motor protection high peak current || 1.1-1.1 kW 440 V AC 50/60 Hz motor protection high peak current || 1.1-1.1 kW 500 V AC 50/60 Hz motor protection high peak current || 1.5-1.5 kW 690 V AC 50/60 Hz motor protection high peak current || 0.63-0.63 kW 230/240 V AC 50/60 Hz transformer protection || 1-1 kW 400/415 V AC 50/60 Hz transformer protection || 1.6-1.6 kW 500 V AC 50/60 Hz transformer protection || 1.6-1.6 kW 690 V AC 50/60 Hz transformer protection || 2-2 kW 690 V AC 50/60 Hz transformer protection
  • Utilisation Category: category A IEC 60947-2 || AC-3 IEC 60947-4-1
  • Fixing Mode: 35 mm symmetrical DIN rail clipped || panel screwed with adaptor plate)
  • [Uimp] Rated Impulse Withstand Voltage: 6 kV IEC 60947-2
  • Control Type: toggle
  • Power Dissipation Per Pole: 2.5 W
  • Electrical Durability: 100000 cycles AC-3 415 V In
  • [Ui] Rated Insulation Voltage: 690 V AC 50/60 Hz IEC 60947-2
  • Breaking Capacity: 100 kA Icu 220/230 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 500 V AC 50/60 Hz IEC 60947-2 || 3 kA Icu 690 V AC 50/60 Hz IEC 60947-2
  • Suitability For Isolation: yes IEC 60947-1 7-1-6
  • Thermal Protection Adjustment Range: 1.6-2.5 A IEC 60947-4-1
  • Tightening Torque: 1.7 N.m screw clamp terminal
  • Mechanical Durability: 100000 cycles
  • Poles Description: 3P
  • Width: 45 mm
  • Depth: 78.5 mm
  • Network Frequency: 50/60 Hz IEC 60947-4-1

Offer Sustainability

  • Rohs Exemption Information: Yes
  • Mercury Free: Yes
  • Environmental Disclosure: ENVPEP121004
  • Sustainable Offer Status: Green Premium product
  • Reach Regulation: Reference contains Substances of Very High Concern above the threshold
  • California Proposition 65: WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
  • Weee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
  • China Rohs Regulation: Product out of China RoHS scope. Substance declaration for your information.
  • Circularity Profile: ENVEOLI121004
  • Eu Rohs Directive: Compliant

Environment

  • Product Certifications: CCC || UL || CSA || EAC || LROS (Lloyds register of shipping) || BV || UKCA
  • Ik Degree Of Protection: IK04
  • Mechanical Robustness: shocks 30 Gn for 11 ms || vibrations 5 Gn, 5…150 Hz
  • Ambient Air Temperature For Operation: -20-60 C
  • Standards: EN/IEC 60947-2 || EN/IEC 60947-4-1
  • Climatic Withstand: IACS E10
  • Ambient Air Temperature For Storage: -40-80 C
  • Ip Degree Of Protection: IP20 IEC 60529
  • Operating Altitude: 6561.68 ft (2000 m)
  • Fire Resistance: 960 C IEC 60695-2-11

Downloads

Spec Sheet

CAD

TeSys GV2 – GV2 MOTOR CB MAGNETIC TOGGLE SWITCH – 3D CAD – MCADPD0003993_2D-back (dxf)
TeSys GV2 – GV2 MOTOR CB MAGNETIC TOGGLE SWITCH – 3D CAD – MCADPD0003993_2D-front (dxf)
TeSys GV2 – GV2 MOTOR CB MAGNETIC TOGGLE SWITCH – 3D CAD – MCADPD0003993_2D-top (dxf)
TeSys GV2 – GV2 MOTOR CB MAGNETIC TOGGLE SWITCH – 3D CAD – MCADPD0003993_2D-left (dxf)
TeSys GV2 – GV2 MOTOR CB MAGNETIC TOGGLE SWITCH – 3D CAD – MCADPD0003993_3D-simplified (stp)
TeSys GV2 – GV2 MOTOR CB MAGNETIC TOGGLE SWITCH – 3D CAD – MCADPD0003993_2D-bottom (dwg)
TeSys GV2 – GV2 MOTOR CB MAGNETIC TOGGLE SWITCH – 3D CAD – MCADPD0003993_2D-right (dwg)
TeSys GV2 – GV2 MOTOR CB MAGNETIC TOGGLE SWITCH – 3D CAD – MCADPD0003993_2D-isometric (dwg)
TeSys GV2 – GV2 MOTOR CB MAGNETIC TOGGLE SWITCH – 3D CAD – MCADPD0003993 (pdf)
TeSys GV2 – GV2 MOTOR CB MAGNETIC TOGGLE SWITCH – 3D CAD – MCADPD0003993_2D-back (dwg)
TeSys GV2 – GV2 MOTOR CB MAGNETIC TOGGLE SWITCH – 3D CAD – MCADPD0003993_2D-front (dwg)
TeSys GV2 – GV2 MOTOR CB MAGNETIC TOGGLE SWITCH – 3D CAD – MCADPD0003993_2D-bottom (dxf)
TeSys GV2 – GV2 MOTOR CB MAGNETIC TOGGLE SWITCH – 3D CAD – MCADPD0003993_2D-right (dxf)
TeSys GV2 – GV2 MOTOR CB MAGNETIC TOGGLE SWITCH – 3D CAD – MCADPD0003993_2D-top (dwg)
TeSys GV2 – GV2 MOTOR CB MAGNETIC TOGGLE SWITCH – 3D CAD – MCADPD0003993_2D-isometric (dxf)
TeSys GV2 – GV2 MOTOR CB MAGNETIC TOGGLE SWITCH – 3D CAD – MCADPD0003993_2D-left (dwg)

Instruction sheet

GV2LE / GV2RT Circuit breakers – Instruction sheet – S1B1986801-06 (pdf)
LAD-311 Motor starter components – TeSys Quickfit Power – 1675442_01A55 (pdf)

Catalog

Catalog Modicon ABT7 ABL6 Single phase transformers 230 to 400 Vac – 25 to 2500 VA – Catalog+Transformers+Modicon+ABT7+and+ABL6+230+V+to+400+V+-+25+VA+to+2500+VA+English+-+october+21 (pdf)

Certificate

CSA Certificate_TeSys GV2ME&GV2RT&GV2P&GV2MC&GV2MP and GV2P Type E & GV2P combined with LC1D09-38 type F – COFC_80115485_EN (pdf)
CB_Certificate_TeSys GV2ME&GV2RT&GV2P&GV2L&GV2LE – CB+cert_GV2_Dijon_Bangpoo_CN55413-M1 (pdf)
CQC_Certificate_TeSys GV2ME&GV2RT&GV2P&GV2L&GV2LE_France – GV2-Dijon_CQC2003010307059256 (pdf)
UL_Certificate_TeSys GV2ME&GV2RT&GV2P&GV2L&GV2LE – E89451-19930716-CertificateofCompliance (pdf)
BV Type Approval Certificate_TeSys GV2ME&GV2RT&GV2P&GV2L&GV2LE – GV2P-L-M-ME-RT_GV2A_05570_F0 (pdf)
RINA Type Approval Certificate_TeSys GV2ME&GV2RT&GV2P&GV2L&GV2LE – RINA_GV2_ELE373320CS (pdf)

Circularity Profile

TeSys GV2 motor circuit breaker – EoLI_ENVEOLI121004EN_V3_1 (pdf)

Environmental Disclosure

TeSys GV2 motor circuit breaker – Internal+PEP+ENVPEP121004EN_V3_1 (pdf)

Declaration of conformity

CCC Self-declaration_TeSys GV2ME&GV2RT&GV2P&GV2L&GV2LE_France – GV2-Dijon_CCC-SDoc_2020980307004793 (pdf)
UKCA Declaration TeSys GV2ME&GV2RT&GV2P&GV2L&GV2LE – UKCA_Doc_SC16041104-UK-GV2L-RT (pdf)
EU Declaration TeSys GV2ME&GV2RT&GV2P&GV2L&GV2LE – EU_DoC_GV2ME%26GV2RT%26GV2P%26GV2L%26GV2LE_SC16041104G (pdf)

Data Bulletin

Motor Control Solutions for the North American Market Data Bulletin – 8536DB0901+R04_23 (pdf)

Videos

Installing Auxiliary Contacts to TeSys GV2 IEC Manual Starters | Schneider Electric Support Mounting & Unmounting TeSys GV Manual Starter to DIN Rails | Schneider Electric Support

Shipping Info Standard Shipping
Free Shipping We offer free shipping on orders over $30. Please check the free - shipping eligibility at checkout.
Delivery Time: It usually takes 3-5 business days for standard shipping. Please note that this is an estimated time frame and may be affected by local holidays, and unforeseen circumstances.