product-details

variable speed drive ATV212 – 55kW – 75hp – 480V – 3ph – EMC class C2 – IP55

0 Reviews
$8,397.35 $147.00
200 in stock

Unconditional Satisfaction Guarantee
No Shipping Fees Above 30
2 Months to Decide. Returns Simplified.

Specifications

  • Product Destination: asynchronous motors
  • Range Of Product: Altivar 212
  • Product Or Component Type: variable speed drive
  • Ip Degree Of Protection: IP55
  • Motor Power Kw: 55 kW
  • Phase: 3 phase
  • Line Current: 102.7 A 380 V || 89 A 480 V
  • [Us] Rated Supply Voltage: 380…480 V – 15…10 %
  • Communication Port Protocol: METASYS N2 || BACnet || Modbus || APOGEE FLN || LonWorks
  • Supply Voltage Limits: 323-528 V
  • Product Specific Application: pumps and fans in HVAC
  • Emc Filter: Class C2 EMC filter integrated
  • Maximum Horse Power Rating: 75 hp
  • Device Short Name: ATV212
  • Supply Frequency: 50…60 Hz – 5…5 %

Contractual warranty

  • Warranty: 18 months

Complementary

  • Prospective Line Isc: 22 kA
  • Electrical Connection: VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES terminal 2.5-2.5 mm / AWG 14 || L1/R, L2/S, L3/T terminal 150-150 mm 300 kcmil)
  • Network Frequency: 47.5…63 Hz
  • Discrete Input Logic: positive logic (source) F, R, RES), <= 5 V, >= 11 V || negative logic (sink) F, R, RES), >= 16 V, <= 10 V
  • Type Of Cable: without mounting kit 1 IEC cable 45 C, copper 90 C / XLPE/EPR || without mounting kit 1 IEC cable 45 C, copper 70 C / PVC || with UL Type 1 kit 3 UL 508 cable 40 C, copper 75 C / PVC
  • Height: 1000 mm
  • Acceleration And Deceleration Ramps: automatic based on the load || linear adjustable separately from 0.01 to 3200 s
  • Analogue Output Type: FM switch-configurable voltage 0…10 V DC 7620 Ohm 10 bits || FM switch-configurable current 0…20 mA 970 Ohm 10 bits
  • Speed Drive Output Frequency: 0.5-200 Hz
  • Discrete Output Type: configurable relay logic FLA, FLC) NO – 100000 cycles || configurable relay logic FLB, FLC) NC – 100000 cycles || configurable relay logic RY, RC) NO – 100000 cycles
  • Transmission Frame: RTU
  • Torque Accuracy: +/- 15 %
  • Asynchronous Motor Control Profile: voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo) || voltage/frequency ratio, 5 points || voltage/frequency ratio – Energy Saving, quadratic U/f || flux vector control without sensor, standard || voltage/frequency ratio, 2 points
  • Maximum Switching Current: 5 A 250 V AC resistive cos phi = 1 L/R = 0 ms FL, R) || 5 A 30 V DC resistive cos phi = 1 L/R = 0 ms FL, R) || 2 A 250 V AC inductive cos phi = 0.4 L/R = 7 ms FL, R) || 2 A 30 V DC inductive cos phi = 0.4 L/R = 7 ms FL, R)
  • Communication Service: read device identification (43) || monitoring inhibitable || time out setting from 0.1 to 100 s || write single register (06) || read holding registers (03) 2 words maximum || write multiple registers (16) 2 words maximum
  • Transient Overtorque: 120-120 % of nominal motor torque +/- 10 % 60 s
  • Insulation Resistance: >= 1 mOhm 500 V DC for 1 minute
  • Response Time: FM 2 ms +/- 0.5 ms analog || FLA, FLC 7 ms +/- 0.5 ms discrete || FLB, FLC 7 ms +/- 0.5 ms discrete || RY, RC 7 ms +/- 0.5 ms discrete
  • Data Format: 8 bits, 1 stop, odd even or no configurable parity
  • Apparent Power: 76.3 kVA 380 V
  • Dielectric Strength: 3535 V DC between earth and power terminals || 5092 V DC between control and power terminals
  • Type Of Polarization: no impedance
  • Frequency Resolution: display unit 0.1 Hz || analog input 0.024/50 Hz
  • Accuracy: +/- 0.6 % VIA) for a temperature variation 60 C || +/- 0.6 % VIB) for a temperature variation 60 C || +/- 1 % FM) for a temperature variation 60 C
  • Switching Frequency: 6…16 kHz adjustable || 8…16 kHz with derating factor
  • Maximum Transient Current: 127.6 A 60 s
  • Connector Type: 1 RJ45 || 1 open style
  • Analogue Input Number: 2
  • Functionality: mid
  • Motor Slip Compensation: adjustable || not available in voltage/frequency ratio motor control || automatic whatever the load
  • Discrete Output Number: 2
  • Minimum Switching Current: 3 mA 24 V DC configurable relay logic
  • Analogue Output Number: 1
  • Physical Interface: 2-wire RS 485
  • Continuous Output Current: 116 A 380 V || 116 A 460 V
  • Number Of Addresses: 1-247
  • Tightening Torque: 0.6 N.m VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES) || 41 N.m, 360 lb.in L1/R, L2/S, L3/T)
  • Discrete Input Type: F programmable 24 V DC level 1 PLC 4700 Ohm || R programmable 24 V DC level 1 PLC 4700 Ohm || RES programmable 24 V DC level 1 PLC 4700 Ohm
  • Speed Range: 1-10
  • Isolation: electrical between power and control
  • Local Signalling: for DC bus energized 1 LED (red)
  • Linearity Error: VIA +/- 0.15 % of maximum value input || VIB +/- 0.15 % of maximum value input || FM +/- 0.2 % output
  • Specific Application: HVAC
  • Output Voltage: <= power supply voltage
  • Nominal Switching Frequency: 8 kHz
  • Width: 362 mm
  • Transmission Rate: 9600 bps or 19200 bps
  • Braking To Standstill: by DC injection
  • Depth: 364 mm
  • Protection Type: overheating protection drive || line supply undervoltage drive || against input phase loss drive || thermal protection motor || motor phase break motor || with PTC probes motor || thermal power stage drive || short-circuit between motor phases drive || input phase breaks drive || overcurrent between output phases and earth drive || overvoltages on the DC bus drive || break on the control circuit drive || against exceeding limit speed drive || line supply overvoltage and undervoltage drive
  • Supply: internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 A overload and short-circuit protection || internal supply 24 V DC 21-27 V), <200 A overload and short-circuit protection
  • Analogue Input Type: VIA switch-configurable voltage 0…10 V DC 24 V max 30000 Ohm 10 bits || VIB configurable voltage 0…10 V DC 24 V max 30000 Ohm 10 bits || VIB configurable PTC probe 0…6 probes 1500 Ohm || VIA switch-configurable current 0…20 mA 250 Ohm 10 bits
  • Sampling Duration: 2 ms +/- 0.5 ms F discrete || 2 ms +/- 0.5 ms R discrete || 2 ms +/- 0.5 ms RES discrete || 3.5 ms +/- 0.5 ms VIA analog || 22 ms +/- 0.5 ms VIB analog
  • Speed Accuracy: +/- 10 % of nominal slip 0.2 Tn to Tn
  • Option Card: communication card LonWorks

Offer Sustainability

  • Rohs Exemption Information: Yes
  • Mercury Free: Yes
  • Environmental Disclosure: ENVPEP111244EN
  • Sustainable Offer Status: Green Premium product
  • Reach Regulation: Reference contains Substances of Very High Concern above the threshold
  • California Proposition 65: WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Weee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
  • China Rohs Regulation: X
  • Circularity Profile: ENVEOLI111242EN
  • Eu Rohs Directive: Pro-active compliance (Product out of EU RoHS legal scope)

Environment

  • Product Certifications: CSA || UL || C-tick || NOM 117
  • Standards: IEC 61800-3 environments 1 category C1 || EN 61800-3 environments 1 category C3 || EN 61800-3 || IEC 61800-3 environments 1 category C3 || IEC 61800-3 environments 1 category C2 || EN 61800-5-1 || IEC 61800-3 environments 2 category C1 || EN 61800-3 environments 2 category C1 || EN 55011 class A group 1 || IEC 61800-5-1 || IEC 61800-3 || EN 61800-3 environments 2 category C3 || EN 61800-3 environments 1 category C2 || IEC 61800-3 environments 2 category C3 || EN 61800-3 category C2 || IEC 61800-3 environments 2 category C2 || IEC 61800-3 category C2 || IEC 61800-3 category C3 || EN 61800-3 category C3 || EN 61800-3 environments 1 category C1 || EN 61800-3 environments 2 category C2
  • Electromagnetic Compatibility: electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 s – 8/20 s surge immunity test level 3 IEC 61000-4-5 || conducted radio-frequency immunity test level 3 IEC 61000-4-6 || voltage dips and interruptions immunity test IEC 61000-4-11
  • Ambient Air Temperature For Operation: -10-40 C without derating) || 40-50 C with derating factor)
  • Shock Resistance: 15 gn 11 ms IEC 60068-2-27
  • Environmental Characteristic: classes 3C1 IEC 60721-3-3 || classes 3S2 IEC 60721-3-3
  • Marking: CE
  • Vibration Resistance: 1.5 mm 3-13 Hz)EN/IEC 60068-2-6 || 1 gn 13-200 Hz)EN/IEC 60068-2-8
  • Noise Level: 63.7 dB 86/188/EEC
  • Pollution Degree: 3 IEC 61800-5-1
  • Regulation Loop: adjustable PI regulator
  • Ambient Air Temperature For Storage: -25-70 C
  • Relative Humidity: 5-95 % without condensation IEC 60068-2-3 || 5-95 % without dripping water IEC 60068-2-3
  • Assembly Style: with heat sink
  • Ip Degree Of Protection: IP55 EN/IEC 61800-5-1 || IP55 EN/IEC 60529
  • Operating Altitude: 3280.84…9842.52 ft (1000…3000 m) limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m || <= 3280.84 ft (1000 m) without derating
  • Operating Position: vertical +/- 10 degree

Downloads

Spec Sheet

Data Bulletin

Grounding and Bonding Practices when Installing Variable Frequency Drives Data Bulletin – 8800DB1501 (pdf)
Service Guide for AC Drives and Soft Starters Data Bulletin – 8800DB0101 (pdf)

User guide

1) ATV212 Quick Start Annex (SCCR and Branch Circuit Protetion) – ATV212_Quick_Start_Annex_S1A73476_05 (pdf)
ATV212 Widget BACnet Integration to EcoStruxure Building Operation Manual – ATV212_Widget_BACnet_to_EcoStruxure_Building_Ope_Manual_EN_JYT47671_02 (pdf)
2) ATV212 Installation manual – ATV212_Installation_manual_EN_S1A53832_04 (pdf)
ATV212 APOGEE FLN P1 manual – ATV212_APOGEE_FLN_P1_manual_EN_S1A53847_01 (pdf)
ATV212 LonWorks manual – VW3A21212 – ATV212_LonWorks_manual_EN_S1A53848_01 (pdf)
ATV212 BACnet manual – ATV212_BACnet_manual_EN_S1A53845_04 (pdf)
ATV212 Metasys N2 manual – ATV212_Metasys_N2_manual_EN_S1A53846_01 (pdf)
3) ATV212 Programming Manual – ATV212_programming_manual_EN_S1A53838_03 (pdf)
ATV212 Modbus manual – ATV212_Modbus_manual_EN_S1A53844_02 (pdf)

Certificate

ATV21-212 UL CERTIFICATE – UL+ATV212+CES (pdf)
ATV21-212 CSA CERTIFICATE – COFC_000070181643_EN (pdf)
ATV212_SE_DECLARATION_PE – SE+Declaration+on+Short+Circuit+to+PE+on+motor+output+-+ATV212-400V (pdf)

Brochure

AC Drives Product Support Group Premier Plan Brochure – 998-20183222 (pdf)
Square D Model 6 Intelligent Motor Control Centers Brochure – 8998BR0001 (pdf)
Altivar 212 Variable Speed Drives Brochure – 8800BR1102_Altivar-212_Brochure (pdf)

Catalog

Altivar 212 and S-Flex Variable Speed Drives Catalog (US 2014) – ATV212eCatalog (pdf)
Altivar 212 variable drives 2011/03 (web PDF format) – Altivar+212+Catalogue_EN_Ed+2011-03+(web) (pdf)
Digest Catalog 26: AC Drives and Soft Starters (OCT 2021) – 0100CT1901_SEC-26_OCT2021 (pdf)

Handout

Altivar 212 Drive Selection Guide Handout – 8800HO1101_Altivar+212+Selection+Guide (pdf)

Instruction sheet

1) ATV212 Quick Start guide – ATV212_Quick_start_EN_S1A53825_03 (pdf)

Software – Release

SoMove (FDT Standalone) – SoMove_V2.9.5_ReadMe (pdf)
ATV212 EBO smart widget XML – ATV212_EBO_smart_widget_V3.2.3.zip
SoMove (FDT Standalone) – SoMove_V2.9.5.exe
SoMove (FDT Standalone) – SoMove_V2.9.5_ReleaseNotes (pdf)

Declaration of conformity

ATV212_UK_DECLARATION – UK_ATV212_UK_DECLARATION_2021_07.docx (pdf)
ATV212 EU DECLARATION – ICD_ATV212_EU_Declaration_2023-06 (pdf)
ATV212 C-TICK CERTIFICATE – ATV212+Ctick (pdf)

Circularity Profile

Altivar 212 – 22 to 75 kW IP55, Product End-of-Life Instructions – ENVEOLI111242EN_V0 (pdf)

Environmental Disclosure

Altivar 212 – 22 to 75 kW IP55, Product Environmental profile – ENVPEP111244EN_V0 (pdf)

DTM files

Altivar DTM Library: ATV12, ATV31/312, ATV32, ATV61, ATV71, ATV LIFT, ATV212 – AltivarDtmLibrary-V12.8.0.exe
Altivar DTM Library: ATV12, ATV31/312, ATV32, ATV61, ATV71, ATV LIFT, ATV212 – AltivarDtmLibrary_v12.8.0_ReleaseNotes (pdf)

CAD

Variable speed drive Altivar 212 UL type 12/IP54 with integrated class A EMC filter, three-phase 400V, 55KW-75HP / 75KW-100HP – 3D CAD – MCADID0000895_2D-bottom (dxf)
Variable speed drive Altivar 212 UL type 12/IP54 with integrated class A EMC filter, three-phase 400V, 55KW-75HP / 75KW-100HP – 3D CAD – MCADID0000895_2D-front (dxf)
Variable speed drive Altivar 212 UL type 12/IP54 with integrated class A EMC filter, three-phase 400V, 55KW-75HP / 75KW-100HP – 3D CAD – MCADID0000895_2D-back (dxf)
Variable speed drive Altivar 212 UL type 12/IP54 with integrated class A EMC filter, three-phase 400V, 55KW-75HP / 75KW-100HP – 3D CAD – MCADID0000895_2D-right (dxf)
Variable speed drive Altivar 212 UL type 12/IP54 with integrated class A EMC filter, three-phase 400V, 55KW-75HP / 75KW-100HP – 3D CAD – MCADID0000895_2D-left (dxf)
Variable speed drive Altivar 212 UL type 12/IP54 with integrated class A EMC filter, three-phase 400V, 55KW-75HP / 75KW-100HP – 3D CAD – MCADID0000895_2D-isometric (dwg)
Variable speed drive Altivar 212 UL type 12/IP54 with integrated class A EMC filter, three-phase 400V, 55KW-75HP / 75KW-100HP – 3D CAD – MCADID0000895_2D-front (dwg)
Variable speed drive Altivar 212 UL type 12/IP54 with integrated class A EMC filter, three-phase 400V, 55KW-75HP / 75KW-100HP – 3D CAD – MCADID0000895_2D-right (dwg)
Variable speed drive Altivar 212 UL type 12/IP54 with integrated class A EMC filter, three-phase 400V, 55KW-75HP / 75KW-100HP – 3D CAD – MCADID0000895_3D-simplified (stp)
Variable speed drive Altivar 212 UL type 12/IP54 with integrated class A EMC filter, three-phase 400V, 55KW-75HP / 75KW-100HP – 3D CAD – MCADID0000895_2D-isometric (dxf)
Variable speed drive Altivar 212 UL type 12/IP54 with integrated class A EMC filter, three-phase 400V, 55KW-75HP / 75KW-100HP – 3D CAD – MCADID0000895_2D-bottom (dwg)
Variable speed drive Altivar 212 UL type 12/IP54 with integrated class A EMC filter, three-phase 400V, 55KW-75HP / 75KW-100HP – 3D CAD – MCADID0000895_2D-top (dwg)
Variable speed drive Altivar 212 UL type 12/IP54 with integrated class A EMC filter, three-phase 400V, 55KW-75HP / 75KW-100HP – 3D CAD – MCADID0000895_2D-left (dwg)
Variable speed drive Altivar 212 UL type 12/IP54 with integrated class A EMC filter, three-phase 400V, 55KW-75HP / 75KW-100HP – 3D CAD – MCADID0000895 (pdf)
Variable speed drive Altivar 212 UL type 12/IP54 with integrated class A EMC filter, three-phase 400V, 55KW-75HP / 75KW-100HP – 3D CAD – MCADID0000895_2D-top (dxf)
Variable speed drive Altivar 212 UL type 12/IP54 with integrated class A EMC filter, three-phase 400V, 55KW-75HP / 75KW-100HP – 3D CAD – MCADID0000895_2D-back (dwg)

Videos

Configuring Reference Switching on Altivar 212 | Schneider Electric Support Locking Altivar 212 Drive Parameter Configuration via Display | Schneider Electric Support Flashing”E”Indicationon theAltivar 212Drive | Schneider Electric Support Configuring Fault Reset Functionality on Altivar 212 Drives | Schneider Electric Support Performing Factory Reset on Altivar 212 | Schneider Electric Support Configuring the ATV212 for Local Mode Operation | Schneider Electric Support Programming Altivar 212 Drive for Freewheel Stop Type | Schneider Electric Support Configuring Altivar 212 Drives for 3 Wire Control | Schneider Electric Support Checking Faults, Motor Voltage & Current in Altivar 212 Fr-F Menu | Schneider Electric Support Programming an ATV212 Drive to Run Using PID Control | Schneider Electric Support Troubleshooting Connection in Progress Message on Altivar 212 Keypad | Schneider Electric Support Programming an ATV212 Drive for 2 Wire Control & VIA as Speed Reference | Schneider Electric Support Configuring ATV212 to Follow Customized Ramp Up/Down Times | Schneider Electric Support Viewing Fault History on Altivar 212 Drive | Schneider Electric Support Configuring Automatic Restart Function on Altivar 212 | Schneider Electric Support

Shipping Info Standard Shipping
Free Shipping We offer free shipping on orders over $30. Please check the free - shipping eligibility at checkout.
Delivery Time: It usually takes 3-5 business days for standard shipping. Please note that this is an estimated time frame and may be affected by local holidays, and unforeseen circumstances.